SOLICITATION NOTICE
41--41 -- Air Exhaust Fans
- Notice Date
- 11/14/2005
- Notice Type
- Solicitation Notice
- Contracting Office
- Attn: Department of Veterans Affairs So. Texas Health Care System, Audie L. Murphy Division, 7400 Merton Minter Boulevard, San Antonio, Texas 78229-4404
- ZIP Code
- 78229-4404
- Solicitation Number
- 671-16Q-06
- Response Due
- 11/29/2005
- Archive Date
- 12/29/2005
- Small Business Set-Aside
- Total Small Business
- Description
- This is a combined synopsis/solicitation for commercial items prepared in accordance with Federal Acquisition Regulation (FAR) Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. Request for Quotations (RFQ) 671-16Q-06 applies and the solicitation is issued as a Request for Quotations (RFQ). This solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular (FAC) 2005-06. This action is 100% Set-Aside for Small Business.. NAICS code 333412 applies. The size standard is 500 employees. Definitions as follows: FAR is Federal Acquisition Regulation, VAAR is Veterans Administration Acquisition Regulation, RFQ is Request for Quotations, CLIN is contract line item number. Prices quoted must be FOB Destination. In order to receive an award Contractors must be registered in Central Contract Registration (CCR). The site is http://www.ccr.gov. CLIN #1 Mark EF1-1, Type- Mixed Flow, Manufacturer & Model, Greenheck QEI-15, Service-General Admin Area, CFM 2,000, S.P. (?WG) 1.50, MAX. BHP 0.80, H.P. 1, V/PH 460/3, Drive, Belt, Control DDC, Note1 1, QUANTITY 1 EACH, CLIN #2, Mark EF1-2, Type- Mixed Flow, Manufacturer & Model, Greenheck QEI-15, Service-Microbiology Lab, CFM 1,840, S.P. (?WG) 1.50, MAX. BHP 0.76, H.P. 1, V/PH 460/3, Drive, Belt, Control DDC, Note 1, QUANTITY 1 EACH, CLIN #3, Mark EF1-3, Type- Mixed Flow, Manufacturer & Model, Greenheck QEI-18, Service-Other Lab Areas, CFM 6,840, S.P. (?W.G) 1.75, MAX. BHP 3.19, H.P. 5, V/PH 460/3, Drive, Belt, Control, DDC, Note 1, QUANTITY 1 EACH, CLIN #4, Mark EF1-4, Type- Mixed Flow, Manufacturer & Model, Greenheck QEI-16, Service-Blood Lab, CFM 4,300, S.P. (?W.G) 1.50, MAX. BHP 1.72, H.P. 2, V/PH 460/3, Drive, Direct, Control, DDC, Note 1, QUANTITY 1 EACH, CLIN #5, Mark EF1-5, Type- Mixed Flow, Manufacturer & Model, Strobic Air, Service-Biosafety Cabinets, CFM 1,320, S.P. (?WG) 1.95, MAX. BHP 2.06, H.P. 3, V/PH 460/3, Drive, Direct, Control, DDC, Notes 2,3,4,5, QUANTITY 1 EACH, NOTES: 1. Provide with NEMA HOA starter, belt guard, flex duct connections and rubber-in-shear suspension isolators, 2. Provide with two (2) complete fans and a common plenum for lead/lag redundancy; plenum shall have an integral bypass damper/actuator and rain hood, side inlet, 3. Fans shall be wired with independent starter/control circuits for dual-point power connection. Provide separate control wiring for bypass actuator, 4. Provide with T.E.F.C. Motor (Chemical Duty), NEMA 3R HOA starter, and manufacturer?s standard 12? tall, 14-GA roof curb, 5. 30-ft minimum effective stack height based on a 10-mph wind. CLIN #6, Mark EF1-6, Type- Mixed Flow, Manufacturer & Model, Strobic Air-TS1, Service-BSL-3, CFM 2,250, S.P. (?WG) 4.10, MAX. BHP 8.4, H.P. 10, V/PH 460/3, Drive, Direct, Control, DDC, Notes 1,2,3,4, QUANTITY 1 EACH, CLIN #7, Mark EF1-7, Type- Mixed Flow, Manufacturer & Model, Strobic Air-TS1, Service-General Exhaust, CFM 1,905, S.P. (?WG) 3.60, MAX BHP 3.5, H.P. 5, V/PH 460/3, Drive, Direct, Control DDC, Notes 1, 2,3,4, QUANTITY 1 EACH, NOTES: 1. Provide with two (2) complete fans and a common plenum for lead/lag redundancy; plenum shall have an integral bypass damper/actuator and rain hood, side outlet, 2. Fans shall be wired with independent starter/control circuits for dual-point power connection, provide separate control wiring for bypass actuator, 3. Provide with T.E.F.C. Motor (Chemical Duty), NEMA 3R HOA starter, and manufacturer?s standard 12? Tall 14-GA roof curb, and 4. 30-ft minimum effective height based on a 10-MPH wind, CLIN #8, Mark EF2-1, Type- Mixed Flow, Manufacturer & Model, Cook 16CVB, Service-General-Lab Area, CFM 1,880, S.P. (?WG) 1.25, MAX. BHP 0.97, H.P. 1-1/2, V/PH 460/3, Max. Sones 21, Drive, Belt, Control DDC, Note 1,QUANTITY 1 EACH, CLIN #9, Mark EF2-2, Type- Mixed Flow, Manufacturer & Model, Cook 28CVB, Service-General-Lab Area, CFM 7,450, S.P. (?WG) 1.35, MAX BHP 3.7, H.P. 5, V/PH 460/3, Max. Sones 27, Drive, Belt, Control, DDC, Note 1, QUANTITY 1 EACH, CLIN #10, Mark EF2-3, Type- Centrif., Manufacturer & Model, Cook 16SQN-HP, Service-General Admin Area, CFM 1,180, S.P. (?WG) 1.00, MAX. BHP 0.37, H.P. ?, V/PH 460/3, Max. Sones 12, Drive, Belt, Control, DDC, Note 1, QUANTITY 1 EACH, CLIN #11, Mark EF2-4, Type- Mixed Flow, Manufacturer & Model, Strobic Air BS00218, Service-Fume Hood, CFM 875, S.P. (?WG) 2.85, MAX BHP 1.95, H.P. 3, V/PH 460/3, Drive, Direct, Plume 26 ft, Control, Continuous, Notes 3,4,5,6, QUANTITY 1 EACH, CLIN #12, Mark EF2-5, Type- Mixed Flow, Manufacturer & Model, Strobic Air BS00218, Service-Fume Hood, CFM 875, S.P. (?WG) 2.85, MAX. BHP 1.95, H.P. 3, V/PH 460/3, Drive, Direct, Plume 26 ft, Control, Continuous, Notes 3,4,5,8, QUANTITY 1 EACH, CLIN #13, Mark EF2-6, Type- Mixed Flow, Manufacturer & Model, Strobic Air BS00218, Service-Biosafety Cabinets, CFM 1,650, S.P. (?WG) 1.50, MAX BHP 2.10, H.P. 3, V/PH 460/3, Drive, Direct, Plume 31 ft, Control, Continuous, Notes 2,4,6, QUANTITY 1 EACH, CLIN #14, Mark EF2-7, Type- Mixed Flow, Manufacturer & Model, Cook 18CVB, Service-Relief, CFM 4,250, S.P. (?WG) 1.50, MAX BHP 2.95, H.P. 3, V/PH 460/3, Max Sones, 34, Drive, Belt, Control, DDC Notes 1,7, QUANTITY 1 EACH, NOTES: 1. Provide with NEMA HOA starter, belt guard, flex duct connections and rubber-in-shear suspension isolators, 2. Provide with two (2) complete fans and a common plenum for lead/lag redundancy; plenum shall have an integral bypass damper/actuator and rain hood, bottom inlet, 3. Fans shall be wired with independent starter/control circuits for dual-point power connection, provide separate control working for bypass actuator, 4. Provide with T.E.F.C. Motor (Chemical Duty), NEMA 3R HOA starter, and manufacturer?s standard 12? tall, 14-GA roof curb, 5. Provide plenum box and bypass damper with actuator and rain hood, side inlet, 6. Plume height based on 10-MPH wind, 7. Provide with Manufacturer?s standard VFD. The provision at FAR 52.212-1, Instructions to Offerors, Commercial Items is applicable. The following addenda to this provision apply: FAR 52.211-6??Brand Name or Equal (Aug?1999) Offerors are to include a completed copy of the provision at FAR 52.212-3, Offeror Representations and Certifications-Commercial Items, with their offeror. The clause at FAR 52.212-4, Contract Terms and Conditions-Commercial Items, applies to this acquisition and will be incorporated in the resultant contract. The following addenda to this clause apply: VAAR 852.211-77 Brand Name or Equal (Nov 1984), and VAAR 852.270-4 Commercial Advertising (NOV 1984).The clause at FAR 52.212-5, Contract Terms and Conditions Required to Implement Statutes or Executive Orders-Commercial Items, applies to this acquisition as noted: (a)(1-2), (b) (1), (5), (7), (9), (14-20), (24), (32), and (e) (1-2), and will be incorporated in the resultant contract. Offerors submitting an equal product must clearly identify the item as an equal and will be required to submit manufacturer?s literature to substantiate that the product is equal. Prospective offerors can access clauses and provisions at the following sites: FAR http://www/acqnet.gov/far, and VAAR http://www.va.gov/oamm/vaar. Quotations are due by close of business November 9, 2005 4:30 pm Central Standard Time. Quotations are to be submitted by e-mail to Hal.Morriss@ med.va.gov and reference RFQ # in the Subject Line. Numbered Note #1 applies.
- Place of Performance
- Address: 7400 Merton Minter Blvd., San Antonio, Tx
- Zip Code: 78229-4404
- Country: United States
- Zip Code: 78229-4404
- Record
- SN00931536-W 20051116/051114211744 (fbodaily.com)
- Source
-
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |