SOLICITATION NOTICE
59 -- Provide Emergency Power to the LinAC
- Notice Date
- 1/6/2005
- Notice Type
- Solicitation Notice
- Contracting Office
- Attn: James A. Haley Department of Veterans Affairs Medical Center, Chief, Acquisition and Materiel Management Service, (90C), 13000 Bruce B. Downs Boulevard, Tampa, Florida 33612
- ZIP Code
- 33612
- Solicitation Number
- 673-39-05
- Response Due
- 1/19/2005
- Archive Date
- 2/18/2005
- Small Business Set-Aside
- N/A
- Description
- This is a solicitation for Commercial Items prepared in accordance with the subparts in Federal Acquisition Regulation 12 (Acquisition of Commercial Items) and with FAR Subpart 13 (simplified Acquisition Procedures). Request for Quotation (RFQ) 673-39-05 is assigned and shall be referenced on any request for solicitation. North American Industry Classification System is 335313. Small Business Size standard is 500 employees. Provide all of the labor, supervision, equipment, and tools to provide emergency power to the LinAC Control Area. Overview: (1) Remove from electrical closet room 32-032: A. One (1) 30 amp, 480-volt, 3 phase disconnect. B. One (1) 15kva277/480/120-volt transformer. C. One (1) 12 Circuit Panel. D. Approximately 160 ft of #10 THHN Cu Conductor. (2) Install one (1) 60 amp I-Line electrical circuit breaker in the Square D panel in the electrical equipment room 32-009. (3) Install one (1) 125 amp, 30 circuit panel w/main breaker, 65K AIC, 3 phase, 480-volt, w/breakers in room 32-032. (4) Install one (1) 60 amp, 3 phase, 480-volt disconnect in room 32-032. (5) Install one (1) 45kva, 277/480/120 volt, 3-phase, dry type transformer, in room 32-032. (6) Install approximately 160 ft of #6 THHN in existing 1? conduit from the electrical panel in room 32-009 to the panel in room 32-032. (7) Install approximately 60 ft of 3/a? EMT from room 32-032 to the computer control area for the LinAcs as shown on the diagram. (8) Install four (4) - #12 CU circuits to the first computer control area, two (2) of which will feed two (2) plug mold strips with six (6) receptacles as shown on diagram. The remaining two (2) circuits will continue to the 2nd computer control area to feed two (2) plug mold strips with six (6) receptacles as shown. All material to be listed by UL or other approved certifying organization. All request for solicitations shall be in writing and sent to the James A. Haley VA Hospital, 13000 Bruce B. Downs Blvd., Tampa, FL 33612 or Faxed to Luisa Rodriguez at 813-972-7572. The Government shall not be held responsible for the quality of fax.
- Web Link
-
RFQ 673-39-05
(http://www.bos.oamm.va.gov/solicitation?number=673-39-05)
- Place of Performance
- Address: 13000 Bruce B. Downs Blvd, Tampa FL
- Zip Code: 33612
- Country: United States
- Zip Code: 33612
- Record
- SN00730875-W 20050108/050106211820 (fbodaily.com)
- Source
-
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |