Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF AUGUST 12, 2004 FBO #0990
SOLICITATION NOTICE

43 -- Rotary Screw Air Compressor System

Notice Date
8/10/2004
 
Notice Type
Solicitation Notice
 
NAICS
332912 — Fluid Power Valve and Hose Fitting Manufacturing
 
Contracting Office
TACOM - Rock Island, ATTN: AMSTA-AQ-AR, Rock Island Arsenal, Rock Island, IL 61299-7630
 
ZIP Code
61299-7630
 
Solicitation Number
W52H09-04-T-0514
 
Response Due
9/30/2004
 
Archive Date
11/29/2004
 
Point of Contact
Christopher Calhoun, (309)782-1086
 
E-Mail Address
Email your questions to TACOM - Rock Island
(calhounc2@ria.army.mil)
 
Small Business Set-Aside
N/A
 
Description
This synopsis is for commercial items/services prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This requirement is for an installed Rotary Screw Air Compressor System that meets the following requirements: a. The rotary screw air compressor shall provide a high temperature cut-off switch. b. The envelope dimension for rotary screw air compressor alone shall not exceed 7in x 8in x 12in. c. The rotary screw air compressor shall provide at least 30 SCFM at 175PSI. d. The rotary screw air compressor weight shall not exceed 50 lb. e. The rotary screw air compressor system shall provide automatic throttle control for the GFE SECM engine. This control will be used to match air demand. f. The air receiver tank shall be incorporated in the system: a. Tank size 3 US. Gallons b. 200 PSI high pressure relief valve c. Integrated coalescing oil separator element d. Lubricant sight glass e. Replaceable spin on 25 micron oil filter with safety bypass feature f. 8 sec. automatic blow down valve g. Envelope dimensions shall not exceed 6.5in dia. x 31in long. h. Weight shall not exceed 20 lb. The Government shall furnish as a part of the contract such technical information and related to performance requirements as necessary for the contractor to perform this contract; to include a GFE SECM and all related technical publications for the SECM an d the HMMWV platform on which the SECM is mounted. The contractor shall mount their proposed rotary screw compressed air system in the GFE SECM. This system shall be mounted under the hood of the GFE SECM. The contractor shall provide a complete set of installation instructions. These instructions will outline in detail all of the necessary steps needed to complete the modification of SECM and installation of the rotary screw air compressor. These instructions shall be prepared in a format of the contra ctor choosing using Microsoft Word and shall be provided to the government for review. The solicitation will be issued electronically on or about 25 August 2004 in accordance with FAR 4.502 and 5.102, therefore, hardcopies will not be provided. POC for this Synopsis is Chris Calhoun, direct line (309) 782-1086, email calhounc2@ria.army. mil, fax: (309) 782-2722.
 
Place of Performance
Address: TACOM - Rock Island ATTN: AMSTA-AQ-AR, Rock Island Arsenal Rock Island IL
Zip Code: 61299-7630
Country: US
 
Record
SN00640681-W 20040812/040810212455 (fbodaily.com)
 
Source
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.