MODIFICATION
A -- Provide Power Feed to CARL
- Notice Date
- 7/26/2004
- Notice Type
- Modification
- NAICS
- 238210
— Electrical Contractors
- Contracting Office
- 1940 Allbrook Drive Suite 3 Wright-Patterson AFB, OH, 45433-5309
- ZIP Code
- 45433-5309
- Solicitation Number
- FA8601-04-R-0063
- Response Due
- 8/16/2004
- Archive Date
- 12/15/2004
- Point of Contact
- Sandy Haught,937-257-6571, ext 4128
- E-Mail Address
-
Email your questions to sandy.haught@wpafb.af.mil
(sandy.haught@wpafb.af.mil)
- Small Business Set-Aside
- Total HUB-Zone
- Description
- UPDATE******UPDATE*****UPDATE The solicitation, drawings, specifications, wage determination, and Addendum #1 have been uploaded to PIXs 7/16/2004. UPDATE*****UPDATE*****UPDATE The response date has been updated from 7/15/2004 to 8/16/2004. UPDATE*****UDATE******UPDATE The work consists of the ability to furnish all materials and perform all labor required to provide power supply for Compression Aero Research Laboratory (CARL) in facilities 20018E and 08185. Project scope is to construct underground cable ducts and provide new medium voltage cables to connect the CARL test apparatus being relocated in Facility 20018E to the base power system at substation C. This work is supporting lab equipment installation. It is recommended that only a qualified electrical contractor with experience in this specific type of work perform this task. The project includes associated architectural, civil, structural, mechanical, plumbing, electrical and miscellaneous work. Special requirements/concerns: This project involves installing new concrete encased duct banks in existing streets, and installing a new 15kV circuit from Substation C to Building 20018E. It is important that the work be completed within the performance period without interruption, and that no unscheduled power outages occur. Traditionally, most medium voltage work has been done by utilities. It is vastly different from performing low voltage (120 or 480V) commercial work. The safety rules and the codes involved are completely different for medium voltage systems versus low voltage systems. Faults on medium voltage systems are much more destructive physically, and much more likely to result in death in case of accidental contact, therefore the different rules. Safety is the primary concern, and this work requires a very specialized contractor with the proper experience. The estimated price range is between 250,000 to 500,000. Period of performance is 240 calendar days. NAICS CODE: 238210. The size standard $12M. This is a restricted procurement in accordance with the HUB Zone Act of 1997 (13 CFR 126), 15 U.S.C. 631 note. In accordance with DFARS 252.204.7004, the contractor must be registered in the CCR prior to award of solicitations issued after 31 May 1998. Tel: 1-888-CCR-2423. FAX: 1-703-696-0213. Every solicitation issued after 31 May 1998 must include the clause at DFARS 252.204-7004, "Required Central Contractor Registration". Registration may be completed via the DUNS/CCR Website: http://www.ccr.gov/. NOTES: 1. The solicitation, specifications and drawings will be available on the World Wide Web on or about 15 July 2004. The web-site address is http://www.pixs.wpafb.af.mil. 2. Hard copies of the solicitation will NOT be provided. You may, however, download and print the file from the World Wide Web. 3. There is no fee for this solicitation. 4. There are approximately 22 pages of the solicitation,approximately 169 pages of the specifications, and approximately 9 sheets of drawings. 5. A hard copy of the solicitation will be available for review at Dayton Builders Exchange, Minority Contractors Business Assistance Program and F. W. Dodge Division. 6. A registration page will be attached to the web-site. You are not required to register. However,when you register, you will receive notice of any amendments and/or addenda that may be issued to the solicitation. If you have not registered, it will be your responsibility to check the web-site for any changes to the solicitation. 7. You shall provide a signed copy of the SF 1442 by the proposal closing date specified in the solicitation. There will NOT be a public bid opening. 8.Contractors that are Debarred, Suspended, or Proposed for Debarment are excluded from receiving contracts. Agencies also shall not consent to subcontract with these contractors. For more information on 04R0063--Provide Power Feed to CARL please refer to http://www.pixs.wpafb.af.mil/pixslibr/04R0063/04R0063.asp
- Web Link
-
04R0063-Provide Power Feed to CARL
(http://www.pixs.wpafb.af.mil/pixslibr/04R0063/04R0063.asp)
- Place of Performance
- Address: Wright-Patterson AFB OH
- Zip Code: 45433
- Country: United States
- Zip Code: 45433