SOURCES SOUGHT
Y -- Provide and install a fully functional turn key Lethal/Non-Lethal fence system at USP McCreary, KY; USP Coleman II, FL; and USP Terre Haute, IN
- Notice Date
- 7/22/2004
- Notice Type
- Sources Sought
- NAICS
- 236220
— Commercial and Institutional Building Construction
- Contracting Office
- Department of Justice, Bureau of Prisons, Construction Contracting, 320 First Street, NW, Room 5002, Washington, DC, 20534
- ZIP Code
- 20534
- Solicitation Number
- RFPX00-0518
- Response Due
- 8/5/2004
- Archive Date
- 8/20/2004
- Point of Contact
- Laurie Williams, Contracting Officer, Phone 202-307-0954, Fax 202-616-6055, - Richard Formella, Contracting Officer, Phone 202-307-0954, Fax 202-616-6055,
- E-Mail Address
-
llwilliams@bop.gov, rformella@bop.gov
- Description
- This is a Sources Sought Notice. The intent of this document is to seek a manufacturer/installer capable of meeting the requirements set forth below. Currently, the Federal Bureau Of Prisons is exploring installing a Lethal/Non-lethal fence system to test at three high security correctional facilities. These facilities include, USP McCreary, McCreary, Kentucky; USP Coleman II, Coleman, Florida; and USP Terre Haute, Terre Haute, Indiana. The Federal Bureau Of Prisons will not offer a ?Hold Harmless? indemnity clause. MANUFACTURER/INSTALLER QUALIFICATIONS: The manufacturer/installer shall possess the ability to provide and install a fully functional turn key Lethal/Non-lethal fence system. The system shall include, but is not limited to: * Lethal/Non-lethal Fence Structure * System High Voltage Energizer * Touch Screen Head End Equipment * Safety Interlocks * Concrete Rat Wall and Sidewalks * Gates and locks The manufacturer/installer shall have provided and or installed a minimum of 3 Lethal/Non-lethal fence systems in the United States. The manufacturer/installer shall demonstrate experience at working in an operating correctional facility. The manufacturer/installer must have the ability to demonstrate to the Government proof of performance of the Lethal/Non-lethal high voltage energizer. The proposed energizer must be in use at an existing site for no less than 2 years. Custom built high voltage energizers will not be considered at this time MINIMUM SALIENT CHARACTERISTICS: High Voltage Energizer The Lethal/Non-lethal high voltage energizer shall have the ability to operate in the following modes: * Non-lethal only * Lethal only * Non-lethal 1st, 2nd and or 3rd attempt then automatically convert to Lethal * Non-lethal, but gateable with other technologies to automatically activate Lethal The High Voltage Energizer must possess an internal full proof interlocking safety system which grounds all conductors when activated. The High Voltage Lethal Energizer must be capable of delivering a minimum AC voltage of 6 KV between phases and 3 KV to ground. The High Voltage Non-lethal Energizer must be capable of delivering a pulsating DC voltage adjustable to 10 KV. The High Voltage Energizer must meet or exceed IEC 335-2-76 standards. System Head End The system head shall be a fully rack-mountable touchscreen Windows based GUI interface which communicates directly with an Alan Bradley Control Logic Series or approved equal PLC (Programmable Logic Controller). SCOPE Of WORK: The manufacturer/installer of the Lethal/Non-lethal fence system must be capable of supporting the following: The Lethal/Non-lethal electrified fence shall consist of a single high voltage energized 12' barrier installed between two existing 12' chain linked fences which surround the institution?s perimeter. The institution?s perimeter is approximately 5000' in length. Wire spacing on the high voltage fence structure shall be a minimum of every 4", starting from the grade beam to 4' in height, and then every 6" there after totaling 26 wires. Insulators shall be arranged to allow a basket weave wire installation. The Lethal/Non-lethal fence shall originate at one side of the institution?s rear gate sallyport, transition overtop of an Administration Building and end at the opposite side of the rear gate sallyport. The Lethal/Non-lethal fence system shall be continuous with no breaks in the fencing structure except at the rear gate sallyport. The Lethal/Non-lethal fence shall be installed as a stand-alone system and be capable of detecting intrusion attempts by zone number. Zone lengths shall be a minimum of 300'. The high voltage fence structure shall be installed on top of a 12" high rat wall flanked by two 48" sidewalks. The Lethal/Non-lethal high voltage energizer/interlock system shall be mounted in a secured exterior enclosure located at or near the rear gate sallyport. The Lethal/Non-lethal touch screen head-end equipment shall be located in the institution?s Control Center. The equipment shall be mounted in the existing control console. Additional bay space may required.
- Place of Performance
- Address: Federal Bureau of Prisons, 320 First Street, NW, 500-6, Washington, D.C. 20534, (202) 307-0954
- Country: USA
- Country: USA
- Record
- SN00628415-W 20040724/040722211831 (fbodaily.com)
- Source
-
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |