MODIFICATION

45 -- UPGRADE EXISTING FIRE SPRINKLER SYSTEM

Notice Date
7/16/2004
 
Notice Type
Modification
 
NAICS
238220 — Plumbing, Heating, and Air-Conditioning Contractors
 
Contracting Office
Department of the Air Force, United States Air Force Europe, 52D Contracting Sqd, Spangdahlem AB Unit 3910 Bldg 2007, Spangdahlem AB, Germany, AE, 09126-3910
 
ZIP Code
09126-3910
 
Solicitation Number
FA5606-04-T-0170
 
Response Due
7/23/2004
 
Archive Date
8/7/2004
 
Point of Contact
Jennifer Rohrbach, Contract Specialist, Phone 0496565619515, Fax 0496565619106,
 
E-Mail Address
jennifer.rohrbach@spangdahlem.af.mil
 
Description
****************************************************** This combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested and a written solicitation will not be issued. This is a Request for Quote. Submit written offers (oral offers will not be accepted), on Solicitation Number FA5606-04-T-0170. Incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2001-24 and Defense Acquisition Circular 91-13. North American Industrial Classification Standard 238220 applies to this procurement. ******************************************************* Non-personal service to upgrade existing fire sprinkler system in Building 61, Bitburg Hospital. Also add a back flow preventer Dn100, and replace clapper valve. Price should include parts, labor, and driving distance for contractor. STATEMENT OF WORK - Fire Suppression System Upgrade. 1. The contractor will provide parts, labor, transportation and freight charges as required to upgrade the existing fire suppression system located in Bldg 61, room 435. 2. The contractor must add back flow prevention device DN 100 (DVGW proof) and replace the existing clapper valve (Make: SFH) DN 100. All other needed replacement parts have been identified on the attached document. 3. The contractor will coordinate, at least 14 days in advance, the specific date and time of each required visit, with the Facility Management department. They can be reached at 06561 693153. 4. All services shall be performed during the hours of 0730 and 1600, Monday through Friday, excluding American holidays. The contractor?s service personnel shall report to the Facility Management office, Bldg 61, room 318, prior to, and upon completion of each required visit. If repair parts are required and must be obtained, the contractor will return with the parts within 24 hours and return the unit to operational condition. 5. All services shall be performed on-site. Equipment will not be removed from the on-site location without consent of the Facility Management personnel. If removal of equipment is required, it will be at no charge to the US government. This includes possible costs incurred for transportation, per diem or mileage. 6. A copy of the service invoice must be left with the Facility Management Office. The invoice will include the following information: hours required performing the service, complete list of repair parts, and a detailed description of all work performed. 7. The contractor must test the system after all work has been completed. A written report of system testing must be provided to the Facility Management Office. PARTS LIST - To upgrade existing sprinkler system in Building 61 (Hospital). Add a back flow preventer DN 100 (DVGW proof) and also replace existing clapper valve (Make: SFH) DN 100. Written report of system testing after completion of work. 1. back flow preventer DN 100 1 each, 2. Flange valves DN 100 2 each, 3. Screen DN 100 1 each, 4. Flap flange DN 100 8 each, 5. Elbow 45 DN 100 2 each, 6. Elbow 90 DN 100 4 each, 7. Fitting DN 100 8 each, 8. Bolts, nuts, gasket set 5 each, 9. Pipe 3 each, 10. Elbow bracket 3 each, 11. Ankers 12 each, 12. Washer 12 each, 13. Nuts 12 each. Change of clapper valve DN 100 ? 14. Clapper valve DN 100 1 each, 15. Wet alarm valve 1 each, 16. Flange valve DN 100 1 each, 17. Screw/nuts/gaskets sets 2 each, 18. Flap flange 2 each, 19. Pipe 1 each, 20. Elbow bracket 2 each, 21. Mounting bracket 8 each, 22. Washer 8 each, 23. Nuts 8 each. ******************************************************* RESPONSE DUE DATE IS 15 JULY 04, 12:00 PM CENTRAL EUROPEAN TIME ******************************************************* THIS PROJECT WILL BE PERFORMED IN ITS INTIRETY IN THE COUNTRY OF GERMANY. THEREFORE THE SOLICITATION IS INTENDED ONLY FOR LOCAL SOURCES IN ACCORDANCE WITH FEDERAL ACQUISITION REGULATION 5.202 (a)(12). LOCAL SOURCES ARE THOSE SOURCES NORMALLY RESIDENT, LICENSED AND REGISTERED TO CONDUCT BUSINESS IN GERMANY. OFFERS FROM NON-LOCAL SOURCES WILL NOT BE CONSIDERED UNDER THIS SOLICITATION. ***************************************************** The Government reserves the right to award on a multiple award or an all or none basis. All quotes must be emailed or faxed to SrA J. Rohrbach at jennifer.rohrbach@spangdahlem.af.mil, facsimile 06565 61 9106. For any questions or concerns, you may call 06565 61 9515.
 
Place of Performance
Address: 52D MEDICAL SQ. UNIT 3690/SGL - F63SGLF, GEB. 149 FLUGPLATZ, SPANGDAHLEM
Zip Code: D-54529
Country: GERMANY
 
Record
SN00625337-W 20040718/040716212131 (fbodaily.com)
 
Source
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.