SOLICITATION NOTICE
23 -- TRAILER, SPECIAL PURPOSE-MOBILE COMMAND POST
- Notice Date
- 7/13/2004
- Notice Type
- Solicitation Notice
- NAICS
- 336214
— Travel Trailer and Camper Manufacturing
- Contracting Office
- Department of the Air Force, Air Education and Training Command, Luke AFB Contracting Squadron, 14100 W. Eagle Street, Luke AFB, AZ, 85309
- ZIP Code
- 85309
- Solicitation Number
- Reference-Number-F1SFTA41820400
- Response Due
- 7/30/2004
- Archive Date
- 8/14/2004
- Point of Contact
- Doug Janders, Contracting Officer, Phone (623) 856-7168 x230, Fax (623) 856-3447,
- E-Mail Address
-
doug.janders@luke.af.mil
- Small Business Set-Aside
- Total HUB-Zone
- Description
- This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. The solicitation number for this procurement is F1SFTA41820400 and is issued as a request for quote. This solicitation and incorporated provisions/clauses are those in effect through FAC 2001-24 and DAC 91-13. This procurement is being issued as 100% HubZone set-aside. NAICS Code: 336214; Size Standard: 500 employees. Funds are currently not available, and may not become available. The requirement is for: CLIN: 0001; Nomenclature: Trailer, Special Purpose, Mobile Command Post, Quantity: One (1); Unit of Issue: Each; Specifications: Pace-American 20 pull trailer, 12?additional ground height; Overall length-23?5?; Box width/OA width-8' 5"/8' 6"; Height-8' 8"; Interior length-20' 5"; Interior height-6' 11"; Axles-Tandem 6000Lb, w/independent torsion suspension and E-Z lube hubs; Brakes-Electric on all axles w/safety breakaway kit with battery; Frame-8" I-beam; Tire size-Goodyear LT235-85R16 LRE covered with aluminum fenders; Wheel size-16" X 8" 8 bolt aluminum; GVWR-2,000Lb with 2-5/16" ball coupler; Payload-7,890Lb; Floorbase-3/4" plywood on 16" O.C. members; Skin-.030" White aluminum sheets w/ galvanized wall beams; Entry doors-2-32" X 78" with screen and window. REQUIREMENTS: (1) Provide and install One (1) Master control console and (a) Contains all switches and equipment controls; (b) 12VDC, 120VAC power distribution panels; and (c) Constructed with 3/4" birch hardwood plywood, covered with Graphite Nebula laminate; (2) Provide and install placards for weight and height; (a) Vehicle height sign on dash; and (b) Vehicle weight sign with axle loads and available axle payload. CEILING: (1) Insulate with PRO-FOAM polyurethane spray foam or equal. R-value of 14; (a) Applied with a minimum coverage of 2" thickness; and (b) Additional R-value of 6 is created when walls and ceilings are built out; (2) Cover interior roof supports for sub-ceiling with 1/4" cabinet grade luan hardwood plywood; (a) Sub-ceiling to be applied with flush head mechanical fasteners spaced on a maximum of 12" centers; (3) Cover sub-ceiling with ribbed, acoustical, flame retardant, and mildew resistant loop pile fabric; (a) Applied with a minimum coverage of 90% spray grade contact adhesive applied to both surfaces; and (b) Color to be determined by customer. FLOOR: (1) Cover interior flooring with 1/4" cabinet grade hardwood plywood; (a) Sub-floor to be applied with flush head mechanical fasteners spaced on a maximum of 12" centers; (2) Cover sub-floor with MANNINGTON resilient flooring; (b) Installed with manufacture recommended adhesive; (3) Provide and install cove base molding at wall/floor interface; (a) 3" high white vinyl material; (b) Secured with silicone based adhesive. WALLS: (1) Insulate with PRO-FOAM polyurethane spray foam or equal. R-value of 14; (a) Applied with a minimum coverage of 2" thickness; (2) Cover interior body side posts for sub-wall with 1/2" cabinet grade luan hardwood plywood; (a) Sub-wall to be applied with flush head mechanical fasteners spaced on a maximum of 16" centers; (3) Cover sub-wall with ribbed, acoustical, flame retardant, and mildew resistant loop pile fabric; (a) Applied with a minimum coverage of 90% spray grade contact adhesive applied to both surfaces; (b) Color to be determined by customer. DOORS: (1) Provide and install two (2) 32" load compartment entrance doors; (a) Aluminum tread-plate step-well; (b) Provided with 20" X 24" fixed window with 1" mini-blinds; (c) Attached to unit with stainless steel hinge; (2) Provide and install One (1) separating bulkhead to be provided; (a) Shall contain 30" pocket door; (i) Utilizing two (2) roller trucks with four (4) wheels each; (ii) Held open with flush mounted flip pin into the floor, and (iii) Held closed with locking pocket door pull; (b) Door to be finished with gloss laminate; (3) Provide and install One (1) lavatory enclosure; (a) Shall contain 24" swinging door; (i) Chrome plated privacy door set, and (ii) Chrome plate butt hinges; (b) Walls and door to be finished with gloss laminate; (c) Enclosure interior dimensions-30"W X 56"L; (4) Provide and install Two (2) exterior entry assist grab handles; (a) Chrome with rubber inserts; (b) 30 degree offset stanchions; (c) Located at all entry doors, and (d) 24" in length; (5) Provide and install Two (2) interior entry assist grab handles; (a) Stainless steel grab bars; (b) Located at entry doors; (c) 30" in length; (6) Doors will be factory furnished finish, OEM; (7) Features common to all doors: (a) All doors to have identical keys; and (b) Install 2" wide, black non-skid tape. ELECTRICAL SYSTEM-120VAC: (1) provide and install One (1) ONAN EMERALD 7 kW Diesel Generator: (a) Generator mounting frame per manufacture recommendations; (b) Exhaust to exit out the side of truck; (c) Chrome exhaust tip directing exhaust down; (d) Remote start with hour meter located in control console; (e) Provide fuel tank; (2) Provide and install One (1) PANELTRONICS 120 VAC Power Distribution panel: (a) UL listed magnetic/hydraulic switch rated circuit breakers; (b) LED indicator light feature; (c) Label backlighting feature: (d) Digital voltmeter; (3) Provide and install One (1) MAGNETEK Automatic transfer switch; (a) Model ATS-50; (b) Located in electric box; (4) Provide and install One (1) HUBBELL shore power inlet: (a) 30 Ampere capacity, Twist lock connectors; (b) Cord hard-wired through 30 ampere double pole circuit breaker; (5) Provide and install One (1) ULTRA-3 75 Ampere power converter: (a) produce a filtered, regulated 12VDC output with a variable input; (b) Units must keep battery voltage within one (1) volt of optimum charge at maximum 12VDC draw; (c) Work in unity with each other without the use of external isolators; (d) Never "over charge" the batteries; (e) Switched on 120VAC power distribution panel; (f) Use of un-regulated power converters with the ability to over charge batteries is not acceptable; (6) Provide and install Six (6) LEVITON specification grade interior duplex wall receptacles: (a) Brushed stainless steel covers; (b) Receptacles located near a source of water will be GFI rated; (c) Locations are shown on attached drawings; (d) Switched on 120VAC power distribution panel; (e) Two (2) dedicated 15 Amp circuits; (7) Provide and install Two (2) LEVITON specification grade GFI exterior duplex receptacles; (a) Exterior grade weather resistant covers; (b) Flush mounted into exterior; (c) Switched on 120VAC power distribution panel; (d) One (1) dedicated 15 Amp circuit; (8) All 120 VAC main wiring; (a) 10 gauge minimum; (9) Branch circuit wiring to be MC stranded 12 gauge: (a) Wiring to be routed using appropriate conduit per application. ELECTRICAL SYSTEM-12VDC: (1) Provide and install four (4) INTERSTATE auxiliary batteries: (a) Sealed gel cell; SG-29; (b) Mounting to be powder coated steel angle and channel uni-frame construction; (c) Shrouding with .063 brite plate; (d) Batteries to be protected with mega fuse or hi-amp circuit breaker; (2) Provide and install One (1) PANELTRONICS 12VDC power distribution panel: (a) UL listed magnetic/hydraulic switch rated circuit breakers; (b) LED indicator light feature; (c) Label backlighting feature; (d) Digital voltmeter; (3) Provide and install Four (4) Interior 12VDC outlets; (a) Cigarette lighter type; (b) Mounted in stainless steel plates at each workstation: (a) 15 Ampere rating per outlet; (4) Provide and install One (1) POWERTEK battery disconnect relay: (a) Controls auxiliary battery system; (b) Current capacity-0 to 300 ADC, 1000 ADC 20 sec; (c) Switched remotely at the dash. Switch to have indicator light; (d) Relay to be placed within 18" of battery; (e) water and Explosion proof. LIGHTING: (1) Provide and install Ten (10) THINLITE 18" fluorescent lights: (a) Mounted on ceiling; (b) Switched from either room from wall switches; (2) Provide and install Three (3) THINLITE fluorescent lights: (a) Model 180, (b) Dual ballast red/white light; (c) Mounted undercabinet at workstations; (3) Provide and install Three (3) WHELEN 810 series relampable halogen light heads: (a) Model 810CAOZR scene lights; (b) 8" X 10" size; (c) Located on curb-side under awning; (4) Provide and install compartment lighting; (a) Activated when door opens; (b) 5" dome light with switch. WIRING REQUIREMENTS: (1) Terminals to conform to MS 25036: (a) Terminals to be crimped with tool recommended by manufacturer; (b) Spade and hook terminals are unacceptable; (2) All wiring to be supported with insulated clamps complying with MS 21919; (3) Wire bundles to be tied with trimmed nylon cable ties; (4) All added DC electrical circuits to be protected by resettable circuit breakers rated for 125% of circuit load; (5) Full wiring schematics are to be provided: (a) 120 VAC main and branch distribution; (b) 2 VDC main and branch distribution; (c) Generator and shore transfer; (d) Audio/video distribution; (e) Low voltage control circuits; (f) Wiring to be color coded; (g) Numbered at both ends; (h) Charted on master wire list; (6) All added wiring to be protected from chafing and abrasion; (7) Electrical installation: (a) Complete 12 VDC system and electrical appliances will be to modern automotive standards through out the installation: (b) Extreme care will be exercised to provide for easy serviceability of the system in the future years; (8) Provide and install HUBBELL basetrack PVC wiring raceways: (a) Provide labeled pull strings for future expansion: (b) Extends from communications closet to the front and rear of unit. INTERIOR FEATURES: (1) Provide and install Two (2) COLEMAN roof mounted heat pump/air conditioners: (a) 15,000 BTUH cooling capacity; (b) 12,700 BTUH heating capacity up to 47degrees F; (c) 5,600 BTUH heating capacity below 47 degrees F; (d) Direct ducting with controls mounted on interior ceiling shroud; (e) Switched on 120VAC power distribution panel; (2) Provide and install Two (2) BROAN wall heaters: (a) Switched from 120VAC power distribution panel; (b) Model 174-1500 watt-5120 BTU/Hr; (3) Provide and install Bench seating: (a) Color coordinated flame resistant CORDURA fabric; (b) 3" Q-41 foam on seat bottoms; (c) 2" Q-41 foam on seat backs; (d) Fabric and foam to conform to FMVSS 302 standards; (e) Cushions to have seamless front construction to minimize wear; (f) Seat back angle to be 75 degrees; (g) Seat bases to be 15" high; (4) Provide and install Six (6) FLEXSTEEL captain's chairs: (a) High back with sliding seat with seat belt; (b) Removable quick-disconnect base; (c) Swivel locks facing forward for transport; (d) Folding arm rests and seat recline; (5) Install Two (2) customer provided white boards: (a) 1-mounted on rear wall in conference room; (b) 1-mounted in communications area; (6) Provide and install fabric covered wire chases: (a) 3/4" X 4" wide; (b) Mounted with chrome trim screws ONLY; (c) Minimum of 3 screws in any one chase cover, with screws placed NO further apart than 24"; (7) Provide and install Safety equipment to consist of the following: (a) two-5lb. ABC rated fire extinguishers: (i) one located inside front door; (ii) one located inside rear door; (b) 2-9VDC smoke detectors; (c) 2-9VDC carbon monoxide detectors (8) Provide and install workstation junction boxes; (a) Located at all workstations; (b) To include the following connectors: (i) RJ-11; (ii) RJ-45; (iii) 12VDC; (iv) 120VAC; (9) Provide and install One (1) map board viewer: (a) 63"W X 37"H X 4"D; (b) Two (2) lights concealed in laminated case; (c) Frosted white plastic material, trimmed with aluminum angle; (d) Located in conference room on back wall. LAVATORY AND GALLEY: (1) Provide and install One (1) NORCOLD DE-0051 refrigerator: (a) Dual voltage-12 VDC/120VAC; (b) Switched from 12VDC power distribution panel; (c) Switched from 120VAC power distribution panel; (d) 1.9 Cubic Feet; (2) Provide and install One BLACK & DECKER coffee maker: (a) Mounted under overhead cabinet in galley; (b) Switched from 120VAC power distribution panel; (3) Provide and install One (1) SHARP or equivalent microwave oven: (a) 700 watt minimum; (4) Provide and install Two (2) stainless steel sinks: (a) 10" X 14" rectangle in galley; (b) 10" X 13" oval in lavatory; (c) Faucets are to be laboratory gooseneck type; (5) Provide and install One (1) SHURFLO water pump: (a) 3.5 GPM; (b) 12 VDC; (c) transparent pump strainer; (d) Switched at tank monitor panel; (6) Provide and install One (1) 30 gallon fresh water supply tank: (a) Polyethylene plastic tank; (b) All connections are to be polyethylene spin fittings; (c) Locked pressure fill with regulator; (7) Provide and install One (1) 35 gallon black holding tank: (a) Polyethylene plastic tank; (b) All connections are to be polyethylene spin fittings; (c) 3" dump valve; (d) 20' dump hose carried in tube mounted under tank; (e) 1 1/2" vent through roof; (8) Provide and install One (1) SYSTEMS MONITOR II tank level meter system: (a) Solid state circuitry; (b) Battery level gauge: (c) Fresh, black and gray tank capabilities; (d) Water pump switch; (9) Provide and install One (1) SEALAND toilet: (a) Model 510 plus, White in color; (b) Porcelain construction; (10) Lavatory shall be equipped with the following: (a) Toilet paper holder; (b) Multi fold paper towel dispenser; (c) 18" X 24" mirror; (d) Light in ceiling, Switched with other ceiling lights; (e) Exhaust fan, 6" diameter, Switch on unit; (11) Provide and install One (1) ARISTON fast recovery hot water heater: (a) 4.0 gallon capacity; (b) Switched from 120VAC power distribution panel; (12) Provide and install Tank heaters and insulation: (a) One (1) AC/DC tank heater per 15 gallons, all tanks heated, (i) Switched from 120VAC power distribution panel, (ii) Switched from 12VDC power distribution panel, (iii) Tank wrapped with minimum 2" fiberglass insulation, (iv) Insulation then wrapped with 3" all weather foil tape; (b) All exposed pipe to be wrapped with 120 VAC heating cable, (i) Switched from 120VAC power distribution panel, (ii) All pipe to be covered with rubber pipe insulation; (13) Plumbing requirements: (a) All pressure pipe to be 1/2" CPVC; (b) All drain and vent pipe to be ABS; (c) All connections to fixtures, appliances and components that may need servicing will use stainless steel flex lines. CABINETS: (1) Construction of all components as follows: (a) Fabricate and install interior compartments, counters, shelves, tables, and work stations per drawings; (b) All components to be constructed of 1/2" and 3/4" A1 grade Birch plywood pre finished with polyurethane; (c) Cases to be of uni-frame to provide light weight durability and flexibility during body flex; (d) All cases and countertops to have post formed, seamless front edges. Preventing chipping of laminate and eliminating sharp edges; (e) All cases and countertops to be covered with high impact plastic laminate, (i) Post formed grade, (ii) Color to be determined, (iii) All doors and drawers to be flush with cabinet faces, Inset style; (f) Install BLUM European style hinges on all doors and lids, 125 degree opening; (g) All drawers and doors will have one (1) SOUTHCO flush mount positive latching pulls on all interior doors and drawers; (h) Provide SPD gas pressurized springs on all upward opening doors, (i) All drawers to have ACCURIDE ball bearing slides, 100 Lb. rating and full extension; (j) Adjustable shelves constructed from 3/4" plywood with 1-1/2" aluminum angle lip; (k) Provide removable conference room table with voice, data and power connections. AUDIO/VIDEO: (1) Provide and install One PANASONIC monitor/receiver: (a) Model CT-2089VYD 20"; (b) Located in overhead console; (c) Switched from 120VAC power distribution panel; (2) Provide and install One (1) PANASONIC DVD/CD/VCR player: (a) Model PV-D4742; (b) DVD-Video discs CDs, audio CD-Rs & CD-RWs, and MP3 CDs; (c) Hi-FI, 4-head VCR; (d) 181 channel tuner; (e) Switched on 120VAC power distribution panel; (3) Provide and install One WINEGARD amplified directional antenna: (a) Mounted on roof towards front of unit; (b) Model #RV-3090. Crank-up style; (c) Amplifier located inside front overhead cabinet; (d) Cable input from street-side to amplifier, placed under exterior cover; (4) Coaxial cable for TV distribution system: (a) BELDEN RG-59 with 20 AWG solid copper center conductor; (b) Nominal attenuation of 6.4 db/100 feet @ 700 Mhz. RADIOS: (1) Pre-wire for Five (5) customer supplied radios: (a) Includes 3/4" NMO bases per specified frequencies; (b) Coaxial cable to be LMR-240; (c) Cable to be run in 3/8" flexible aluminum conduit; (d) 12 VDC 3/8" stud type junction posts at pre-wire locations; (2) Provide and install One PIONEER AM/FM/CD player and speakers: (a) Model DEH-1400 deck mounted in console; (b) Model TS-A1661 speakers mounted in trim panels; (c) Antenna provided and mounted up on front side corner. TELEPHONE SYSTEM: (1) Provide and install Five CO landline inputs: (a) RJ11 connector; (b) Located on street-side; (c) Mounted under exterior weatherproof cover; (2) Provide and install Four (4) interior telephone extension jacks: (a) 4-RJ11 connector; (b) 2-located at workstations, and 2-on conference table; (c) Mounted in stainless steel covers; (3) Provide and install One line dedicated to the fax machine; (4) Provide and install One HEWLETT PACKARD all in one fax: (a) Model 2210 or equal; (b) Network capable; (c) Mounted on slide-out tray; (5) Provide and install One (1) GLOBALSTAR satellite phone: (a) Model 1600 tri-mode; (b) Satellite or cellular service assured; (c) Optional data cable-9600 KBPS; (d) Optional hands free kit. COMPUTER EQUIPMENT: (1) Provide and install One 10BaseT computer network: (a) 4-RJ-45 connectors; (b) Category 5 cabling; (c) Data switch located in utility closet; (d) Input located on street-side behind driver?s door; (2) Provide and install One LINKSYS network switch: (a) 5 port model; (b) Located in communications closet. EXTERIOR COMPARTMENT: (1) Provide and install Three WEATHERGARD steel storage boxes: (a) One 18"H X 36"L X 18"D for electrical box; (b) One (1) 18"H X 36"L X 24"D for battery box; (2) Generator compartment to be constructed as follows: (a) 100" diamond plate aluminum sheeting; (b) Full length aluminum hinge; (c) All doors to have industrial grade EDPM seal; (d) Door hardware to consist of polished stainless steel, locking paddle handle, and rotary latch with safety catch; (e) Downward opening door to be held open at 90 degrees with aircraft type cable and swaged fittings; (f) Compartments to be lined with DRI-DEK to provide moisture protection of stored equipment; (g) All compartment to have identical keyed locks. EXTERIOR EQUIPMENT: (1) Underbody to be undercoated on all exposed metal; (2) Provide and install One CAREFREE OF COLORADO awning, 20' in length; (3) Provide and install Two HICKORY SPRINGS pull-out steps: (a) Mounted under curb-side entry doors; (b) Manual operation. OTHER EQUIPMENT: (1) Provide and install One RDS aluminum fuel tank: (a) Capable of holding 40 gallons diesel fuel; (b) Provide fuel fill on street-side; (c) Provide fuel for generator; (2) Provide and install One road-side safety kit: (a) Includes 3- reflective triangles; (b) Marking flares. PAITING SPECIFICATIONS: (1) Paint preparation for exterior, to consist of the following processes: (a) Fully sanded to assure removal of imperfections in surfaces; (b) All sheet metals to be chemically etched with acid type cleaners; (2) Entire trailer to be WHITE. WARRANTY: Two year, unlimited mileage against defects in materials and workmanship. TRAINING/OPERATION: (1) Contractor shall be responsible for providing on-site customer training to include but not limited to: (a) Four (4) hours training for instructors; (b) Four hours for drivers, operators, maintenance personnel, and other personnel; (2) Training subjects to include: (a) Generator/Shore power systems use and maintenance; (b) 12VDC and control systems use and maintenance; (c) Communications systems use and maintenance; (d) Audio/Video systems use and maintenance; (e) Water systems start-up and shut-down procedures with simulation exercises. This requirement is for delivery FOB Destination to Luke AFB, Arizona. Be sure to specify proposed delivery time. The provision at FAR 52.212-1, Instructions to Offerors--Commercial Items, applies. Offerors are required to submit a completed copy of FAR 52.212-3, Offeror Representations and Certifications -- Commercial Items, with their quote, which can be found at http://www.farsite.hill.af.mil. The clause at FAR 52.212-4,Contract Terms and Conditions-Commercial Items, applies to this acquisition. The clause at FAR 52.212-5 (Dev), Contract Terms and Conditions Required To Implement Statutes or Executive Orders--Commercial Items, applies to this solicitation. Specifically, the following clauses cited are applicable to this solicitation: 52.232-33, Payment by Electronic Funds Transfer--Central Contractor Registration. and 52.252-2, Clauses Incorporated by Reference 42.202-1, Definitions; 52.203-3, Gratuities; 52.203-11, Certification and Disclosure regarding Payments to Influence Certain Federal Transactions; 52.203-12, Limitation on Payments to Influence certain Federal Transactions; 52.219-14, Limitations on Subcontracting; 52.222-1 Notice to the Government of Labor Disputes; 52.222-3, Convict Labor; 52.222-19, Child Labor?Cooperation with Authorities and Remedies; 52.222-21, Prohibition of Segregated Facilities; 52.222-26, Equal Opportunity; 52.222-35, Equal Opportunity for Special Disabled Veterans, Veterans of the Vietnam Era, and Other Eligible Veterans; 52.222-36, Affirmative Action for Workers with Disabilities; 52.222-37, Employment Reports on Special Disabled Veterans, Veterans of the Vietnam Era, and other Eligible Veterans; 52.225-13, Restrictions of Certain Foreign Purchases; 52.225-15, Sanctioned European Union Country End Products; 52.225-16, Sanctioned European Union Country Services; 52.233-3, Protest After Award; 52.242-15, Stop-Work-Order; 52.253-1, Computer Generated Forms; 52.219-3, Notice of HubZone Set Aside; 52.232-18, Availability of Funds; 52.247-34, FOB Destination are applicable. The clause at DFARS 252.212-7001, Contract Terms and Conditions Required to Implement Statues or Executive Orders applicable to Defense Acquisition of Commercial Items, applies to this solicitation. Specifically, the following clauses cited are applicable to this solicitation: DFARS 252.225-7001, Buy American Act and Balance of Payment Program and DFARS 204-7004, Required Central Contract Registration; 252.209-7001, Disclosure of Ownership or Control by the Government of a Terrorist Country; 252-209-7004, Subcontracting with Firms that are Owned or Controlled by the Government of a Terrorist Country; 252.219-7011, Notification to Delay Performance; 252.243-7001 Pricing of Contract Modifications; 252.243-7002, Requests for Equitable Adjustment; 252.246-7000, Material Inspection and Receiving Report; 252.247-7023, Transportation of Supplies by Sea. To be eligible to receive an award resulting from this solicitation, contractor must be registered in the DoD Central Contractor Registration (CCR) database. To register, you may apply through the Internet at http://www.ccr.gov. A firm-fixed price award will be made based on price and price related factors. All quotes may be emailed to doug.janders@luke.af.mil or faxed to (623) 856-3447 ATTN: Doug Janders. Quotes are required to be received NLT 4:00 PM AM PST, 30 Jul 04. Offer acceptance period must extend through 30 Sep 04.
- Place of Performance
- Address: Luke AFB, Arizona
- Zip Code: 35309
- Zip Code: 35309
- Record
- SN00619921-W 20040715/040713211940 (fbodaily.com)
- Source
-
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |