SOLICITATION NOTICE
61 -- Transfer Switch and Fuse Cabinet as made by S&C Electric Company, 6601 North Ridge Boulevard Chicago, IL 60626-3997 USA Phone: (773) 338-1000
- Notice Date
- 6/16/2004
- Notice Type
- Solicitation Notice
- Contracting Office
- Bureau of Reclamation, Northern California Area Office 16349 Shasta Dam Blvd Shasta Lake CA 96019
- ZIP Code
- 96019
- Solicitation Number
- 04SQ230045
- Response Due
- 6/24/2004
- Archive Date
- 6/16/2005
- Point of Contact
- Loraine D. Collins Contracting Officer 5302762051 lcollins@mp.usbr.gov; Steve Peay Elec. Eng. 5305295322 speay@mp.usbr.gov;
- E-Mail Address
-
Email your questions to Point of Contact above, or if none listed, contact the IDEAS EC HELP DESK for assistance
(EC_helpdesk@NBC.GOV)
- Small Business Set-Aside
- N/A
- Description
- This announcement serves as a notice of intent to solicit and negotiate with only one source under the authority of FAR Part 6.302-1. This notice will be the only notice prior to negotiation and award of the contract. Our requirement from S & C Electric Company will be the exact replacement of existing S&C System II switchgear. The existing 12, 470-volt distribution system consists of 6 S & C System II cabinets side by side. The existing S&C System II Outdoor Metal Enclosed Switchgear is described by S&C # CDA-726262. The new switchgear will feature identical enclosure dimensions and style. The new bus will readily mate with the existing bus. The new switchgear shall consist of 2-Bays, which are labeled 1A and 1B. These will mate with existing CDA 726262 Bay-2. Government forces will remove the existing Bay-1 cabinet. The new switchgear Bay-1B will exactly replace existing Bay-1. Each new Bay will match the existing old Bay dimensions 90"H x 46"D. The new switchgear will match the features of the existing, including interrupter switch components, viewing windows, copper main bus, copper ground bus, and outdoor gray finish. The ratings are also consistent with existing, at 600 ampere continuous, 13.8KV nominal, 95KV BIL, 14KA Short circuit RMS Symmetrical, 22,400 Amperes RMS Symmetrical 2 times duty cycle fault close. The anticipated award date is June 25, 2004. All inquires and concerns must be addressed in writing to the Contracting Officer, Attn: NC-801, 16349 Shasta Dam Blvd., Shasta Lake, CA 96019-8400. Inquires shall be received by June 22, 2004.
- Web Link
-
Please click here to view more details.
(http://ideasec.nbc.gov/j2ee/announcementdetail.jsp?serverId=BR142520&objId=110228)
- Place of Performance
- Address: U.S. Fish and Wildlife 24411 Coleman Hatchery Road Anderson, CA
- Zip Code: 960079715
- Country: USA
- Zip Code: 960079715
- Record
- SN00604698-W 20040618/040616212500 (fbodaily.com)
- Source
-
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |