28 -- SF6 GAS COMPRESSORS AND BLAST VALVE

Notice Date
6/1/2004
 
Notice Type
Solicitation Notice
 
Contracting Office
00017 - US BUREAU OF RECLAMATION P O BOX 620 - CODE 7810 GRAND COULEE WA 99133
 
ZIP Code
99133
 
Solicitation Number
04SQ170814
 
Response Due
6/15/2004
 
Archive Date
6/1/2005
 
Point of Contact
Pam Marrs - Fax 509-633-9175 Purchasing Agent 5096339512 pmarrs@pn.usbr.gov;
 
E-Mail Address
Email your questions to Point of Contact above, or if none listed, contact the IDEAS EC HELP DESK for assistance
(EC_helpdesk@NBC.GOV)
 
Small Business Set-Aside
Total Small Business
 
Description
This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR SubPart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the solicitation. The Bureau of Reclamation, Grand Coulee Power Office, Grand Coulee WA has a requirement for SF6 gas compressors and blast valves. This is a small business set-aside requirement. The NAICS Code is 333912 and the size standard is 500 employees. Delivery is to be made to the Bureau of Reclamation, Warehouse B - Door 6 - Industrial Area, Grand Coulee WA 99133. The Request for Quotation (RFQ) is being issued as 04SQ1700814 and quotes (including product specification literature and completed 52.212-3 Offeror Representations and Certifications-Commercial Items) are due June 15, 2004. The RFQ incorporates revisions and clauses in effect through FAC 2001-22. The Government anticipates an award of a firm-fixed price resulting from this RFQ on or about June 16, 2004. Following are the applicable provisions and contract clauses incorporated by reference: FAR 52.212-1 Dated January 2004 Instructions to Offerors-Commercial Items; FAR 52.212-3 Dated January 2004 Offeror Representations and Certifications-Commercial Items; FAR 52.212-4 Dated October 2003 Contract Terms and Conditions-Commercial items; FAR 52.212-5 Dated January 2004 Contract Terms and Conditions Required to Implement Statutes or Executive Orders-Commercial Items, paragraph b is edited to incorporate the following clauses: 52.222-3 Convict Labor, 52.222-19 Child Labor-Cooperation with Authorities and Remedies, 52-222-21 Prohibition of Segregated Facilities, 52.222-26 Equal Opportunity, 52.222-35 Equal Opportunity for Special Disabled Veterans, Veterans of the Vietnam Era, and Other Eligible Veterans, 52.222-36 Affirmative Action for Workers with Disabilities, 52.222-37 Employment Reports on Special Disabled Veterans, Veterans of the Vietnam Era and Other Eligible Veterans, 52.225-1 Buy American Act-Supplies, 52-225-13 Restriction on Certain Foreign Purchases, 52.232-33 Payment by Electronic Funds Transfer-Central Contractor Registration. CLIN 0001: COMPRESSOR, SF6 gas, two-cylinder, reciprocating compressor designed for gas. Cylinders and cylinder heads are identical. Disc-type suction and discharge valves are used in the cylinder heads. Precision ground, hardened-steel wrist pins attach the pistons to the connecting rods. A rotary sliding vane type oil pump supplies oil to moving parts of the compressor. The crankshaft and flywheel are balanced to provide for smooth operation. The combination flywheel is used as a drive pulley and a cooling fan. A spring actuated rotary oil seal proves a positive seal at the crankshaft-flywheel end. O-rings and gaskets are used to form a gas tight seal at the valves, cylinder heads, and cylinders. An oil level sight gage is located in the side of the crankcase to observe oil level. Summit Electric Part No. 2063C39H01, or equal. Specify warranty. Quantity 2 each. CLIN 002: BLAST VALVE, 4 PORT, remanufactured. The blast valve piston located in the end of the high pressure reservoir controls the flow of gas from the reservoir to the interrupting units. The sliding valve design minimizes the forces due to gas pressure tending to hold the valve in the closed position. The flow of gas from the auxiliary reservoir to the interrupter unit is sealed by a Teflon seal ring and the rounded lip on the piston bearing against a valve seat. A bumper of reinforced laminated rubber absorbs the energy of the piston as it nears the end of its open position travel. Summit Electric Part No. 5605D55G04R, or equal. Specify warranty. Quantity 6 each. CLIN 003: TRADE IN of the old blast valve of a Westinghouse 550 SFA Breaker S/N 2-62Y5529. Credit for trade in of old blast valve sent back when remanufactured valve has been installed. Quantity 1 each. If quoting equipment other than specified, list information about equipment on quote. Include estimated delivery date after receipt of order. All offerors must provide enough product specification details for adequate evaluation by the Government. Quotes may be submitted electronically or via fax. Any respondents to this announcement may fax your company name, complete address, Dun and Bradstreet number, Federal Tax ID number, contact name, phone and fax number and completed quote to Pamala Marrs at 509-633-9175. All questions should be submitted in writing and may be faxed.
 
Web Link
Please click here to view more details.
(http://ideasec.nbc.gov/j2ee/announcementdetail.jsp?serverId=BR142517&objId=36472)
 
Record
SN00595361-W 20040603/040601212027 (fbodaily.com)
 
Source
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.