Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF SEPTEMBER 24, 2003 FBO #0666
SOLICITATION NOTICE

65 -- Electrocardiograph

Notice Date
9/22/2003
 
Notice Type
Solicitation Notice
 
Contracting Office
European Regional Contracting Cell, ATTN:MCAA E, Building 3705, Landstuhl, Germany APO, AE 09180
 
ZIP Code
09180
 
Solicitation Number
DADA19-03-T-0149
 
Response Due
9/27/2003
 
Archive Date
11/26/2003
 
Point of Contact
THEODORE FRANK, cc(49)6371868761
 
E-Mail Address
Email your questions to European Regional Contracting Cell
(theodore.frank@lnd.amedd.army.mil)
 
Small Business Set-Aside
N/A
 
Description
NA This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are b eing requested and a written solicitation will not be issued. Item 1: Electrocardograph (quantity 10 each) with the following specifications or equivilant: data storage and retrieval of ECGs; adult and pediatric interpretive ECG analysis with signal averag ing program; 15-lead acquistion, storage and analysis Digital Compact Acquistion Module; Remote Query software; Performance Specifications: Microprocessor augmented automatic electrocardiograph; 14-leadwire acquisition with programmable lead configurations; PROCESSING ECG interpretation: Adult and Pediatric ECG Analysis Program; Computerized measurements: 15-lead analysis includes measurements of user-selectable additional 3 leads; Additional ECG function: Vectorcardiography; ECG analysis frequency: 500 samples/second ( sps); ECG storage: 150 typical, 200 ECGs maximum on removable media (1.44 MB, 3.5diskette); Digital sampling rate: 4000 samples/second/channel; Pre-acquisition: Provides 10 seconds of instantaneous ECG acquisition; Dynamic range: AC differential: ????10 mV DC offset: ????320 mV; Resolution: 4.88 ????V/LSB @ 500 sps; Frequency response: ??????3 dB @ 0.01 to 150 Hz; Common mode rejection: greater than140 dB (123 dB with AC filter disabled); Input impedance: greater than10M@ 10 Hz, defibrillator protected; Patient leakage: less than10 ????A; Pace detect: Orthogonal LA, LL and V6; 750 ????V @ 50 ????s; Special acquisiti on functions: Disconnected lead detection, electrode impedance, excessive AC noise, baseline wander and muscle tremor messages; Heart rate meter: 30 to 300 BPM ???? 10% or 5 BPM whichever is greater. COMMUNICATIONS: Modem and Fax transmission, Remote Retri eval (Remote Query); DISPLAY: Display type: 264 mm (10.4 in) diagonal graphics backlit AM LCD; Display resolution: 640 x 480 pixels with waveform enhancement; Display data: Heart rate, patient name, ID, clock, waveforms, lead labels, speed, gain and filter settings, warning messages, prompts and help messages; Writer technology: Thermal dot array; Writer speeds: 5, 12.5, 25 & 50 mm/s (same as displayed); Number of traces 3, 6, 12 or 15, user selectable (same as displayed); Writer sensitivity/gain: 2.5, 5, 1 0, 20, 10/5 (split calibration) mm/mV (same as displayed); Writer speed accuracy: ????2%; Writer amplitude accuracy: ????5%; Writer resolution: Horizontal 1000 dpi @ 25 mm/s, 200 dpi vertical; Paper type: Thermal, Z-fold, perforated, fan fold, 300 sheets/p ack; Paper size: A size: 214.63 mm x 280 mm (8.45 in x 11 in) A4 size: 210 mm x 297.5 mm (8.27 in x 11.7 in); KEYBOARD Type: Sealed elastomer with soft function keys, alphanumeric keys, writer controls and TrimPad cursor controls; ELECTRICAL Power supply: AC or battery operation Voltage: 100 to 240 VAC +10, -15%; C urrent: 0.5A @ 115 VAC, 0.3 A @ 240 VAC, typical; Frequency: 50 to 60 Hz????10%; Battery type: User replaceable, 18V @ 3.5 AH ???? 15%,rechargeable NiMH Battery capacity: 100 single page reports (typical) or6 hours continuous display (without printing); Battery charge time: Approximately 4.5 hours from total discharge (with display off); VECTORCARDIOGRAPHY: Report formats: Vector loops of component vectors (P, QRS, ST-T) Sensitivity: 20, 40, 80 or 160 mm/mV; Time resolution: 2 ms; SIGNAL-AVERAGED ELECTROCARDIOGRAPHY; Frequency response/input: -3 dB @ 0.01 and 250 Hz; Frequency response/output: Upper limit: 250 Hz; Lower limit: 0.01, 25, 40 or 80 Hz; Sensiti vities: Raw data and template: 20 mm/mV; Average beat: 20 mm/mV and 50 mm/mV; Filtered signals and vector magnitude: 1 mm/????V; Analysis sampling rate: 1000 samples/second/channel; Digital sampling rate: 4000 samples/second/channel; High/low pass filters: Special filter using Fast Fourier Transform (FFT); ADC resolution: 1.22 ????V/LSB; Analysis resolution: 0.1525 ????V/LSB. Item 2) Trolley system for electrocardiograph (quantity 10 each). Two copies each of operators and service manuals will be required. Interested parties should quote FOB terms destination Landstuhl Reg ional Medical Center, Landstuhl Germany, and indicate earliest delivery date. FAR Clauses 52.212-4, 52.212-5 as well as DFAR Clause 252.204-7004 and 252.229-7002 are applicable to this action and can be viewed at http://farsite.hill.af.mil/. Solictation m ay be requested by phoning cc49-6371-868761,via fax at cc49-6371-868070, or via e-mail from theodore.frank@lnd.amedd.army.mil
 
Place of Performance
Address: European Regional Contracting Cell ATTN:MCAA E, Building 3705 Landstuhl, Germany APO AE
Zip Code: 09180
Country: GE
 
Record
SN00439391-W 20030924/030922213323 (fbodaily.com)
 
Source
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.