SOLICITATION NOTICE
61 -- power distribution panel (NSN: 6110-01-248-6671)(MIL P/N P0029183/19)
- Notice Date
- 7/3/2003
- Notice Type
- Solicitation Notice
- Contracting Office
- Department of the Air Force, Direct Reporting Units, 11th CONS, 110 Luke Avenue (Bldg 5681) Suite 200, Bolling AFB, DC, 20332-0305
- ZIP Code
- 20332-0305
- Solicitation Number
- Reference-Number-F3046531540100
- Response Due
- 7/17/2003
- Archive Date
- 8/1/2003
- Point of Contact
- William Bickley, Contract Specialist, Phone 202-767-0298, Fax 202-767-7887, - Regina Morris-Malone, Contract Specialist, Phone (202) 767-8033, Fax (202) 767-7887,
- E-Mail Address
-
william.bickley@bolling.af.mil, regina.morris@bolling.af.mil
- Small Business Set-Aside
- Total Small Business
- Description
- This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. This solicitation is issued as Reference No. F3046531540100. The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular (FAC) 2001-14 & Class Deviation 2002-o0003. This is a small business set-aside. The North American Industry Classification System code is 335311 (formerly SIC code 3612) at 750 employee size standard. CLIN 0001 Power Distribution Box/Panel, NSN 6110-01-248-6671, P/N MIL ? P-0029183/19, QUANTITY: 1, UNIT: Each, UNIT PRICE: __________, NET AMOUNT: ____________. PROPOSED DELIVERY DATE: _______________. Prices should be quoted FOB: Destination. A complete price breakdown is required as part of your offer for the line item listed above. Also, the contractor shall be responsible for any FAR PROVISIONS: The provisions at 52.212-1, Instructions to Offerors-Commercial Items and 52.212-3, Offerors Representation and Certifications-Commercial Items are hereby incorporated. Addendum to FAR Clause 52.212-1 applies to this acquisition as follows: 52.252-1. Offeror must include, with its offer, a completed copy of provision FAR 52.212-3 in full text. The Government will award a contract resulting from this solicitation to the responsible offeror whose offer conforms to the solicitation and price is determined most advantageous to the Government. FAR CLAUSES: The clause at 52.212-4, Contract Terms and Conditions-Commercial Items is hereby incorporated. Addendum to FAR Clause 52.212-4 applies to this acquisition, specifically the following cited clauses: 52.219-6, 52.252-2, 52.253-1, 252.204-7004, 252.212-7001, 252.225-7001, and 252.247-7023. FAR Clause 52.212-5, Contract Terms and Conditions Required to Implement Status of Executive Orders-Commercial Items apply to this acquisition, specifically, the following cited clauses: 52.222-3, 52.233-3, 52.222-21, 52.222-26, 52.222.36, 52.222-19, 52.225-1, and 52.232-33. An official authorized to bind your company shall sign the offer. To be eligible for an award, all contractors must be registered in the Central Contractor Registration (CCR). A contractor can contact the CCR by calling 1-888-227-2423 or e-mail at http://www.ccr.gov/. The FAR clauses web site is http://farsite.hill.af.mil or www.arnet.gov. Questions concerning this solicitation should be addressed to William T. Bickley, Contract Specialist, Phone (202) 767-0298, FAX (202) 767-7887, E-mail to: William.Bickley@bolling.af.mil. SPECIFICATIONS: POWER DISTRIBUTION PANEL, 100KW NSN 6110-01-248-6671 MIL P/N P-0029183/19 Dimensions and Weight: 75" X 33" X 32", 450 Pounds Input Power Requirements: 120/208V, 3 phase, 60 Hz, Y Connection 4 wire and ground Bus Capacity: 400 Amperes Circuit Capacity: Quantity Circuit Kind Circuit Breaker Pole(P)-Ampere(A) Interface Connector 2 120/208V 3 phase 4P, 5W 3P-400A (MAIN) Terminal Blocks 4 120/208V 3 phase 4P, 5W 3P-100A MS90555C44412S 10 120/208V 3 phase 4P, 5W 3P-60A MS90555C32412S Wiring Assignments: Connector Terminal Wiring Circuit Function Connector Type Phase A black wire Phase B red wire Phase C blue wire Neutral white wire Ground green wire 1 Input Terminal block T1 T2 T3 T0 G 2 Optional Terminal block P1 P2 P3 P0 G 3,4,5,6 Branch MS90555C44412S A B C N G 7,8,9,10,11,12,13,14,15,16 Branch MS90555C32412S A B C N G
- Place of Performance
- Address: , Prices should include FOB Destination:, Bolling AFB, DC
- Zip Code: 20032
- Country: USA
- Zip Code: 20032
- Record
- SN00363785-W 20030705/030703213524 (fbodaily.com)
- Source
-
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |