Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF MAY 24, 2003 FBO #0541
SOLICITATION NOTICE

41 -- Ceiling Mounted Air Handler CCP2 Pipe Chilled Water Fan

Notice Date
5/22/2003
 
Notice Type
Solicitation Notice
 
Contracting Office
Department of State, Office of Logistics Management, Acquisition Management, P.O. Box 9115 Rosslyn Station, Arlington, VA, 22219
 
ZIP Code
22219
 
Solicitation Number
1030-3HBA24
 
Response Due
6/3/2003
 
Archive Date
6/18/2003
 
Point of Contact
Laverne Lyons, Purchasing Agent, Phone 7038756029, Fax 7038756292,
 
E-Mail Address
lyonslg@state.gov
 
Small Business Set-Aside
Total Small Business
 
Description
NOTE: Brand Name or Equal (Must Specify), please provide GSA Schedule if applicable.No Split Shipment will be allowed. Point of Contact:Attn: LaVerne Lyons-Jones at(703)875-6029,fax quote to (703) 875-6292.This procurement will be ship to: Springfield, Va. 22150.Please e-mail all questions to LyonsLG@state.gov. 1). Ceiling Mounted Air Handler CCP2 pipe chilled Water Fan Coil Nominal Capacities 09-48k BTU/H 208/230V, 60HZ, Model # CCP09D; Total Capacity 13300; Sensible Capacity 9800; Fluid Temp. 45; Fluid Flow 3; including the following a) Relays and Connections for Chilled Water Supply, b)Unit Mounted Digital Control as standard, c)Indoor Coil Freeze Protection, d) Auto/High/Low Fan Operation, e)Cabinet in White, f)Condensate Drain Pan, made from galvanized steel with anticorrison coating (3 each); 2).Ceiling Mounted Air Handler CCP2 pipe chilled Water Fan Coil Nominal Capacities 09-48k BTU/H 208/230V, 60HZ,Model # CCP09D; Total Capacity 10900; Sensible Capacity 8800; Fluid Temp. 45; Fluid Flow 2; Including the following: a) Relays and Connections for Chilled Water Supply, b)Unit Mounted Digital Control as Standard, c)Indoor Coil Freeze Protection, d)Auto/High/Low Fan operation, e)Cabinet in White, f)Condensate Drain Pan, made from galvanized steel with anticorrison coating;(2 each)3).Ceiling Mounted Air Handler CCP2 pipe chilled Water Fan Coil Nominal Capacities 09-48k BTU/H 208/230V, 60HZ,Model # CCP09D; Total Capacity 7900; Sensible Capacity 7300; Fluid Temp. 45; Fluid Flow 1; including the following: a)Relays and Connections for Chilled Water Supply, b)Unit Mounted Digital Control as Standard, c)Indoor Coil Freeze Protection, d)Auto/High/Low Fan Operation, e)Cabinet in White, f)Condensate Drain Pan, made from galvanized steel with anticorrison coating (1 each); 4)Ceiling Mounted Air Handler CCP2 pipe chilled Water Fan Coil Nominal Capacities 09-48k BTU/H 208/230V, 60HZ, Model # CCP12D; Total Capacity 15600; Sensible Capacity 10700; Fluid Temp. 40; Fluid Flow 3; including the following: a)Relays and Connections for Chilled Water Supply, b)Unit Mounted Digital Control as Standard, c)Indoor Coil Freeze Protection, d)Auto/High/Low Fan Operation, e)Cabinet in White f)Condensate Drain Pan, made from galvanized steel with anticorrison coating (1 each); 5). High Wall Air Handler WCP 2 Piped Chilled Water Fan Coil Unit, 208/230V, 60HZ, Model # WCP09D; Total Capacity 7375; Sensible Capacity 6732; Fluid Temp. 45; Fluid Flow 1:a) Relays and Connections for Chilled Water Supply, b) Unit Mounted Digital Control as Standard c)Indoor Coil Freeze Protection, d)Auto/High/Low Fan Operation, e) Cabinet in White, f) Condensate Drain Pan, made from galvanized steel with anticorrison coating (12 each); 6). High Wall Air Handler WCP 2 Piped Chilled Water Fan Coil Unit, 208/230V, 60HZ, Model # WCP09D; Total Capacity 10801; Sensible Capacity 8272; Fluid Temp. 45; Fluid Flow 2 a) Relays and Connections for Chilled Water Supply, b) Unit Mounted Digital Control as Standard, c) Indoor Coil Freeze Protection, d) Auto/High/Low Fan Operation, e) Cabinet in White, f) Condensate Drain Pan, made from galvanized steel with anticorrison coating (1each); 7). High Wall Air Handler WCP 2 Piped Chilled Water Fan Coil Unit, 208/230V, 60HZ, Model # WCP15D; Total Capacity 15625; Sensible Capacity 13477; Fluid Temp. 45; Fluid Flow 2 a) Relays and Connections for Chilled Water Supply, b) Unit Mounted Digital Control as Standard, c)Indoor Coil Freeze Protection, d)Auto/High/Low Fan Operation, e)Cabinet in White, f)Condensate Drain Pan, made from galvanized steel with anticorrison coating (1 each); 8)High Wall Air Handler WCP 2 Piped Chilled Water Fan Coil Unit, 208/230V, 60HZ, Model # WCP24D; Total Capacity 29031; Sensible Capacity 21178; Fluid Temp. 45; Fluid Flow 6, a)Relays and Connections for Chilled Water Supply, b)Unit Mounted Digital Control as Standard, c)Indoor Coil Freeze Protection, d)Auto/High/Low Fan Operation, e)Cabinet in White, f)Condensate Drain Pan, made from galvanized steel with anticorrison coating (1each); 9)High Wall Air Handler WCP 2 Piped Chilled Water Fan Coil Unit, 208/230V, 60HZ, Model # WCP24D; Total Capacity 32320; Sensible Capacity 22539; Fluid Temp. 45; Fluid Flow 9, a)Relays and Connections for Chilled Water Supply b)Unit Mounted Digital Control as Standard, c)Indoor Coil Freeze Protection, d)Auto/High/Low Fan Operation e)Cabinet in White, f)Condensate Drain Pan, made from galvanized steel with anticorrison coating (2 each); 10). Hand Held Infra-Red Remote Controller, Model 240-3455 for WCP 2 Units on lines 5 through 9 above (19 each); 11) Hand Held Infra-Red Remote Controller, Model CHPIR for CCP 2 Units on lines 1 through 4 above (7 each); 12) Additional, Permanent, Washable Electrostatic Filter for WCP2 Units on lines 5 through 9 (19 each); 13)Additional , Permanent, Washable Electrostatic Filter for CCP2 Units on lines 1 through 4. (7 each); 14).Condensate Pump, Model W208CP for WCP Units on lines 5 through 9 (19 each);15).Condensate Pump, Model C208CP, for CCP Units on lines 1 through 4 above (7 each);16). Chilled Water Control Valves 3 Way Power Open/Normally Closed 8VA MAX Model # VT3213G13A020 (Mfg. Erie) for WCP Units on lines 5 through 9 (7 each); 17). Chilled Water Control Valves 3 Way Power open/Normally Closed 8VA MAX, Model # VT3313G13A20 (Mfg. Erie) for CCP Units on lines 1 through 4.(7 each); 18). Estimated Transportation Charges.(1 Lt)
 
Place of Performance
Address: U.S. DEPARTMENT OF STATE, Department of State, Office of Logistics Management, Acquisition Management, P.O. Box 9115 Rosslyn Station, Arlington, VA.
Zip Code: 22219
 
Record
SN00330643-W 20030524/030522213341 (fbodaily.com)
 
Source
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.