Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF DECEMBER 15, 2002 FBO #0378
SOURCES SOUGHT

49 -- Iron Phosphate Spray System for Batch Pretreatment Oeprations

Notice Date
12/13/2002
 
Notice Type
Sources Sought
 
Contracting Office
Department of the Navy, Naval Air Systems Command, Naval Air Warfare Center Aircraft Division Lakehurst, Contracts Department Hwy. 547 Attn:B129-2, Lakehurst, NJ, 08733-5083
 
ZIP Code
08733-5083
 
Solicitation Number
N68335-03-RFI-0031
 
Archive Date
1/15/2003
 
Point of Contact
Charles Discenza, Contract Specialist, Phone 732-323-2076, Fax 732-323-7531, - Daniel McClure, Contracting Officer, Phone 732-323-2801, Fax 732-323-2359,
 
E-Mail Address
charles.discenza@navy.mil, daniel.mcclure@navy.mil
 
Description
This is a request for information only. There is no solicitation package available. The Naval Air Warfare Center Aircraft Division Lakehurst is seeking sources that may be capable of providing an iron phosphate spray system for batch pretreatment operations on bare metal components prior to powder coating. The iron phosphate system shall comprise an Aaladin 8430 Electric iron phosphatizing unit, or equivalent, in addition to a containment booth with wastewater treatment tank integral to the floor for holding all of the wastewater generated and for neutralization prior to discharge. A pump shall be included in order to pump the wastewater out when the tank is full. The system shall be designed to be placed on an existing concrete floor with no excavation whatsoever required. The largest component to be processed shall measure 9' w x 28' l. The booth shall include a crane slot for an overhead conveyor. Ventilation shall be provided capable of replacing the entire interior volume of air within a 3 minute interval. Any and all exhaust stacks shall include filters to return the vapor to the wastewater holding tank. Sufficient lighting shall be provided to adequately illuminate the interior of the booth during spraying operations. An air hose shall be provided for manual drying of the components after treatment. It is expected that the electrical requirement shall be for 460V, 3 ph power. Standard pressure compressed air requirements and water requirements are also anticipated. Please discuss the utility requirements of your equipment if they deviate from these figures as well as the interior and exterior dimensions and layout of the booth in your response to this RFI. Brochure type photos would be helpful, as well as an approximate price and General Service Administration (GSA) availability. The Government will not pay for any information received in response to this request nor will the Government compensate any respondent for any costs incurred in developing the information provided to the Government. Responses should cite the RFI Number N68335-03-RFI-0031 and be addressed to the attention of Mrs. Joyce Discenza, Code 25222JD, Hwy. 547, Bldg. 562-1, Naval Air Warfare Center Aircraft Division Lakehurst, N.J. 08733-5104. All responses are due by 31 December 2002.
 
Record
SN00223416-W 20021215/021213213833 (fbodaily.com)
 
Source
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.