Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF NOVEMBER 23, 2002 FBO #0356
SOLICITATION NOTICE

W -- Rental, High Pressure Air Compressor

Notice Date
11/21/2002
 
Notice Type
Solicitation Notice
 
Contracting Office
N00102 Building 153, 6th Floor Portsmouth, NH
 
ZIP Code
00000
 
Solicitation Number
N0010203Q1229
 
Archive Date
1/5/2003
 
Point of Contact
Kathleen Barry 207-438-3866 Patricia Vachon 207-438-3866
 
E-Mail Address
Email your questions to click here to contact contract specialist
(barrykm@mail.ports.navy.mil)
 
Description
This is a combined synopsis/soliciation for commercial items prepared in accordance with the format in FAR Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitues the only solicitation; quotations are being requested and a written solicitation will not be issued. This announcement is issued as N00101-03-Q-1229 and incorporates clauses effective through acquisition circular 2001-09 with changes effective through 9/30/2002 and DFARS current as of 10/25/02 and inclusive of DCN 20021025 effective 10/25/02 This acquisition is not reserved for a small business set aside. The NAICS Code is 333912. The provisions at 52.212-1, Instructions to Offerors--Commercial, applies to this acquisition. Offerors are requested to include a completed copy of the provision at 52.212-3 and 252-212-7000, Offeror Representations and Certification s--Commercial Items, with quotations. The following clauses/provisions apply to this acquisition: 52.212-4, 52.212-5 (including 52.222-21, 52.222-22, 52.222-25, 52.222-26, 52.222-35, 52.222-36, 52.222-37, and 52.225-3), and 252.212-7001. (Note: Federal Acquisition Regulation (FAR) text is available at http://www.arnet.gov/far.) Clause may be viewed in full text. Quotations shall include the vendor?s cage code, DUNs number, and TIN (taxpayer identification number). Quotations may be faxed to (207) 438-1251 Attn: Kathleen Barry, or mailed/e-mailed or hand delivered to Portsmouth Naval Shipyard, Contracting Division, Building 153, 6th Floor, Code 531.1A, Portsmouth, NH 03801-2590 and are due no later than 11 December 2002 at 3:30 PM local time. Point of contact is Kathleen Barry, Contracting Officer, at 207-438-3866 or E-mail barrykm@mail.ports.navy.mil. Quotations shall be eval uated on lowest priced technically acceptable offer who meets all the requirements of the quotation and is otherwise eligible to receive an award. The prospective awardee must be registered with Central Contractor Registration (CCR) prior to award. For more information on CCR, call 888-227-2423 or log on to www.ccr.dlis.dla.mil. W--SECTION C - DESCRIPTION/SPECIFICATIONS SPECIFICATION FOR AN ELECTRIC MOTOR DRIVEN HIGH PRESSURE AIR COMPRESSOR AND DRYER ASSEMBLY. Qty 1 each C.1 The Unit is to be an Air Cooled High Pressure Air Compressor with appropriate air purification system to be able to deliver 15-20 CFH air at 5000 psig. The compressed air to be dried to a Dewpoint of (-) 60 degrees F at atmospheric pressure. (+20F at 4500 psig), and contain not more than 1 ppm/w Oil Vapor in the final discharge air. The Air Compressor shall have not less than 5 compression stages with appropriate intercoolers and aftercooler so as to provide discharge air temperatures of 100F or lower. C.2 The Compressor/Dryer assembly shall be a complete operating Unit as described in this section when delivered. If required, contractor service shall be provided within 24 Hours after notification by the contracting officer or his representative. In the event the machine cannot be returned to service within 48 hours of notification, a replacement shall be delivered at no extra charge to the government. C.3 The Unit shall be Electric Motor driven at 460VAC, 60 Hertz, with a maximum motor speed of 1800 rpm, and motor horsepower not less than 75 HP. The motor to be suited for outdoor operation in 0 degrees F temperatures without the need for additional shelter. The motor to be air cooled, totally enclosed and size shall be up to 100 hp. C.4 The air compressor shall be able to continuously compress free air to 5000 psig, and have a discharge capacity of 15 to 20 CFH at 5000 psig. The Unit is to be enclosed in a weather-proof enclosure. An Air Receiver of at least 1.5 cubic feet shall be attached to the Unit to eliminate short-cycling of the compressor. The Receiver shall have a pressure relief valve and manual drain valve installed. C.5 Compressor and Motor Controls and Safety Equipment shall be installed as part of the Unit. These shall include, but are not limited to: High Pressure Stop Switch, High Temperature Cutout Switch, Stage Safety Valves, Low Oil Pressure Cutout Switch, Overload Circuit Breakers or Fuses. The compressor shall meet ASME Power Piping requirements and electrical components are to meet NEC requirements for service intended. Safety Controls shall include a full voltage magnetic moto r starter, indicators and safety shutdowns for compressor and air system protection. C.6 Individual Stage Condensate Drains - both automatic and manual drain valves shall be installed, with a Condensate Collection system consisting of a 15 gallon or larger sump equipped with a manual drain valve. Automatic Condensate Drains may be either timed or level sensing. Manually operated drain valves are to be installed as a backup in case the automatic drains fail. C.7 Air Purification Equipment consisting of a Moisture Separator capable of being blown down manually; One or more Oil/Particulate Filters (Coalescing Filters) are to be installed downstream of the Moisture Separator. The Oil/Particulate Filter(s) shall be capable of removing particulate matter as small as 15 Microns. The Filters shall contain replaceable Cartridges and be comparable to CUNO Micro Clean Filter Cartridge No. 2278-B2 or U78-B2 or better. An Air Drying method shall be installed to bring the final air quality to a Dewpoint of minus 60 degrees F when measured at atmospheric pressure. Regenerative Tower type dryers are NOT acceptable due to the excessive amount of controls and maintenance required on those devices. Air Dryer assemblies shall be equipped with a Back Pressure Regulating Valve (Priority Valve) at the discharge end of the dryer unit to prevent a large pressure drop accross the air dryer assembly. C.8 All Spare Parts for the Compressor Unit shall be furnished by the contractor. The contractor shall be responsible for on-site startup and all routine maintenance, i.e.: change oil, filters, lubricants, coolant, etc., except for daily check of liquid levels. The contractor shall maintain a stringent Maintenance program and be responsible for equipment failu re not arising out of abuse or negligence by the government. The contractor shall provide Training for the shipyard compressor operators, and provide complete Operating Instructions. C.9 The equipment shall be wired electrically to enable a single point Shipyard connection. On the final High Pressure Air Discharge connection, the contractor shall have installed a  inch IPS Union Tailpiece for connection to Shipyard systems. The connecting tailpiece shall have 1 3/4?-12 male threads on the Union Tailpiece so as to be adaptable to a Shipyard furnished Nut and Tailpiece with the O-ring on it. C.10 The Contractor shall provide a point of contact and telephone number for use in requesting service if a problem arises with the equipment. Name__________________ Telephone No.________________ Location____________________ C.11 The rental period is approximately 13 w eeks beginning 1/9/2003 through 3/10/2003. Delivery to Subbase NLON, Groton, CT. Point of Contact to be provided.
 
Web Link
the description above is the solicitation
(http://www.neco.navy.mil)
 
Record
SN00209242-W 20021123/021122064212 (fbodaily.com)
 
Source
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.