SOLICITATION NOTICE
65 -- 65-Alice 4 Acquisition System (Sleep Lab)
- Notice Date
- 11/21/2002
- Notice Type
- Solicitation Notice
- Contracting Office
- Attn: Department of Veterans Affairs So. Texas Health Care System, = Audie L. Murphy Division, 7400 Merton Minter Boulevard, San Antonio, Texas = 78229-4404
- ZIP Code
- 78229-4404
- Solicitation Number
- 671-9Q-03
- Archive Date
- 1/5/2003
- Point of Contact
- Point of Contact - Joe Ortiz, Purchasing Agent, (210) 617-5147, Co= ntracting Officer - Joe Ortiz, Purchasing Agent, (210) 617-5147
- E-Mail Address
-
Email your questions to Joe Ortiz
(joe.ortiz@med.va.gov)
- Description
- This is a combined synopsis/solicitation for commercial items prepare= d in accordance with the format in FAR 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotations are being requested and a written solicitation will not be issued. Solicitation documents incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2001-09. This procurement is unrestricted. The NAICS is 421450. Prospective offers are required to submit written or faxed quotations. The South Texas Veterans Health Care System (STVHCS), Audie L. Murphy Division, 7400 Merton Minter Blvd, San Antonio, Texas 78229 has a requirement to purchase one (1), Respironics Inc, ALICE 4 Acquisition System (Sleep Lab) unit, Model #H3030. Unit includes the following accessories; one (1) each, Alice 4 amplifiers; one (1) each, Alice patient Junction box; one (1) each, Alice4 Ethernet Lan Adapter; one (1) each, cabling; one (1) each, Software; one (1), 3300 Adult accessory Packages; one (1) each, Tranquility Bi-level Units. Also a Stardust System, that includes, one (1) each Stardust Recorder with Pressure Based Flow, Software; one (1) each and Three to Four days of on-site installation and training. Description of Alice 4 Acquisition System: This system will be utilized to gather and analyze data from patient to diagnose sleep disorders. This unit is able to collect data in a stand-alone mode (no computer necessary) or while connected to a computer running Alice Sleepware. In either mode, all collected signals may be viewed. The unit=92s sophisticated touch screen gives you full bedside control =96 including acquisition start/stop, impedance check, calibration signal generation, and review of waveform data. You can even enter patient information and create or modify acquisition montages. Complete bedside control enables patient disturbances to be kept to a minimum and the technician=92s time to be used more efficiently. The Alice 4 has built in flexibility for communication, networkable amplifiers, data storage/retrieval and field upgrade ability. It can transfer data via modem, Ethernet or fax.=20 Data storage options include PCMCIA card, network drive and various other storage media. On board oximetry and remote titration of Respironics pressure therapy devices minimize cables and ancillary devices in the patient room. All software updates for this system=92s configurations will be at no charge on this generation of product.=20 Vendor will provide three or four days of on-site installation and training to facility at no additional charge. Technical support will be provided for staff 24 hours a day, seven days a week (excluding holidays). Specifications: 8 Referential, EOG, EMG,; Full set of PSG Parameters w/up to 8 Analog Auxiliary Signal Inputs. Automatic analysis provided for SpO2, ph, EtCO2, CPAP, bi-level. =B31MW, =B1156uV, 8 or 10 bits, up to 200Hz, 30Hz, =B10.03uA Square wave between patient electrodes; Signal injection, 1Hz, 80uVpp Square wave to amplifier inputs; Data is sent from Alice 4 Amplifier to the Computer via Ethernet connection using TCP/IP Protocol. Direct serial or optical serial interfaces to Respironics serial communication enabled pressure therapy devices. Flash memory or PCMCIA hard drives used for real-time data storage in the amplifier. 0.5 to 100Hz High Pass Filter; 0.5 to 100Hz Low Pass Filter; and 50 to 60 Hz Notch filter. Manufacturer is Respironics Inc. Quotations shall include all warranty information, technical data, etc. Quotations shall be submitted F.O.B. destination. All quotations are to include a completed copy of the provisions at 52.212-3; Offer representations and Certifications-Commercial Items, with quotation (a copy of this provision may be requested by facsimile to (210) 617-5255, Attention: Joe Ortiz). The following provisions and clauses apply to this action; 52-212-4, Contract Terms and Conditions Commercial Items, 52-212-5, ContractTerms and Conditions Required to Implement Statues and Executive Orders =96 Commercial Items including clauses incorporated by reference under Section b (11-16)(19)(21-22)(25),52-212-1, Instructions to Offerors-Commercial Items VAAR clause 852.211-77 Brand name or equal, 852.211-70 Requirements for Operating and Maintenance Manuals, 852.211-71 Guarantee Clause and 852.270-4 Commercial Advertising. Delivery of items must be available on or before December 23, 2002 to meet government requirement. E-mail quotations are unacceptable. Offers are to be submitted written or by facsimile to (210) 617-5255, attention Joe Ortiz by Close of Business (COB) 4:30 P.M. CST on December 6, 2002.
- Web Link
-
RFQ 671-9Q-03
(http://www.bos.oamm.va.gov/solicitation?number=3D671-9Q-03)
- Record
- SN00208996-W 20021123/021122063557 (fbodaily.com)
- Source
-
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |