SOLICITATION NOTICE
Y -- Construct a Fire Cache building approximate 40-44 X 110-120= Ft for Badlands National Park
- Notice Date
- 9/19/2002
- Notice Type
- Solicitation Notice
- Contracting Office
- MWR - Black Hills Contracting - Mt Rushmore National Memorial Box 268, Hwy 244 Keystone SD 57751
- ZIP Code
- 57751
- Solicitation Number
- I1505020120
- Point of Contact
- Ron Eilefson Contract Specialist 6055743130 Ron_Eilefson@nps.gov
- E-Mail Address
-
Email your questions to Point of Contact above or IDEASEC HELP DESK
(IDEAS_EC@NBC.GOV)
- Small Business Set-Aside
- N/A
- Description
- Specifications for Badlands Fire Cache Approximate dimensions =3D 40-44 ft. X 110-120 ft. =B7 Garage dimensions =3D 40-44 ft. X 60 ft. (3 20 ft. wide bays) =B7 Office area dimensions =3D 40-44 ft. X 50-60 ft. General =D8 ?Best? locks on all personnel doors =D8 gutters and downspouts front and back =D8 2? roof overhang preferred =D8 snow load 30psf minimum, wind speed 90mph minimum =D8 all windows slide-by with screen =D8 4x12 roof slope maximum; less preferred =D8 4? minimum concrete slab thickness; 4,000psi minimum =D8 strip topsoil, over-excavate, at least 24? compacted fill =D8 floor level at least 1 ft. above current grade for drainage =D8 radiant heat system; hanging or in-floor in garage, in-floor in office area =D8 government will place utilities within 5 ft. of slab =D8 sprinkler system in offices minimum =D8 Roofing: galvanized steel, 29 gauge; tan or sandstone in color; R2= 2 minimum insulation; vented =D8 Siding: galvanized steel, 29 gauge; tan or sandstone in color; textured preferred =D8 Exterior walk-in doors: metal, commercial grade, insulated, 3 heavy-duty hinges, in metal frames with weather stripping; R15 minimum;= deadbolt lock =D8 Exterior walls: R19 minimum insulation =D8 Interior walls: 2X4 construction; sound insulation in all offices a= nd baths/showers =D8 Interior doors (office area): solid core wood commercial grade; 1.5= inch thick minimum; oak veneer finish; lever-type handles =D8 Interior doors (in garage?4); metal commercial grade, 3 heavy-duty hinges =D8 Lighting (office area): appropriate for office work; energy efficient fluorescent =D8 Lighting (garage): suspended energy efficient fluorescent =D8 Water Heater: 40gal or greater capacity =D8 All oak trim in office area =D8 Plumbing: all lavatories and toilets have independent water shut-of= f valves; porcelain china lavatories, toilets, urinal; fiberglass shower enclosures; 1frost-free exterior faucet =D8 Floor Coverings: commercial grade, low-level loop carpet installed= in meeting room, offices, hallway; vinyl floor covering in restrooms, showers, HVAC room, laundry =D8 Cabinets: all oak veneer; counter-tops Formica finish with back splash =D8 Telephone/computer jacks: 3 per office; 12 in meeting room; 1 in weight room =D8 Exit lights at both walk-in exterior doors Garage area =D8 3 Overhead drive-in doors 12 ft. X 12 ft. =B7 framed door openings =B7 Chain lift, electronic operation =B7 2 small windows/door =B7 insulated =B7 concrete-filled pipe bollards on each side of each door =D8 Concrete slab with minimum 4 ft. apron in front of garage =B7 Oil/sand separator and drain =D8 1 metal, insulated 3 ft. wide walk-in door w/ half window (insulate= d glass), handicap access handle =D8 2 slide-by windows along side wall 3 ft. X 6 ft. or approximate =D8 3 slide-by windows along back wall (centered on each bay) 3 ft. X 6= ft. or approximate =D8 radiant heat (floor or hanging) on separate programmable thermostat= =D8 insulated walls and ceiling =D8 utility sink Office/Meeting area =D8 smoke detectors =D8 HVAC, radiant heat, air conditioning; on programmable thermostat separate from garage =D8 Fire wall separates from garage (if required by code) =D8 4 metal, insulated 3 ft. wide walk-in doors w/ half window, handica= p access handle =D8 ?weight room?: approximately 16 ft. X 20 ft. =B7 finished sheet rock; 3 ft. X 6 ft. window or approximate; concrete= floor; suspended acoustic ceiling, oak trim =D8 ?fire cache? (storage): approximately 12 ft. X 20 ft. =B7 finished sheet rock; concrete floor; suspended acoustic ceiling =D8 ?SAR cache?: approximately 12 ft. X 20 ft. =B7 finished sheet rock; concrete floor =D8 ?meeting/eating room?: approximately 20 ft. X 34 ft. =B7 finished sheet rock; suspended acoustic ceiling; commercial grade carpet; oak trim; recessed lighting; =B7 double stainless steel kitchen sink in cabinet with counter; singl= e lever faucet; overhead cabinets including microwave cabinet =D8 baths/ showers =B7 1 ADA bath w/ shower; commercial tile floor or linoleum; solid, oak-finish door; finished sheet rock or similar walls; suspended ceilin= g; cabinet over toilet; exhaust fan w/ timer switch =B7 1 non-ADA shower, separate from bath; glass shower door; small dressing area; commercial tile floor or linoleum; waterproof walls and ceiling; solid, oak-finish door; exhaust fan w/ timer switch =B7 1 non-ADA bath w/ urinal; commercial tile floor or linoleum; solid= , oak-finish door; finished sheet rock or similar walls; suspended ceiling; lav in cabinet; exhaust fan w/ timer switch =D8 offices: approximately 10 ft. X 11 ft. each =B7 1 slide by window in each; 3 ft. X 6 ft. =B7 finished sheet rock; oak trim; solid, oak-finish doors; suspended ceiling; recessed lights Badlands Fire Cache Foundation text This building will be built on flat grassland with highly expansive bentonitic clay soil. Based on borings and lab analysis, this building= should be supported by drilled pier-grade beam type foundation or supported by spread footing foundations bearing on a minimum of 5 feet = of granular engineered fill. The floor will be a concrete slab above grad= e bearing on a minimum of 5 feet of granular engineered fill. The slab should be above grade in order to facilitate run-off and so that eroded= soil from the surrounding badlands will not be deposited against the building structure. This solicitation will be issued O/A September 13,2= 002 and available on the Department of Interior website at (http://ideasec.nbc.gov) and returned complete to Mt. Rushmore National= Memorial, Box 268, Keystone, SD 57751 This Procurement is being conducted as a "Best Value" Procurement using the rules of FAR 12 and public law 100-656 the Competitiveness Demonstration Program allowing small an= d large businesses to compete, contractor will be evaluated on Experience, Past Performance and Price. HARD COPIES OF THIS SOLICITATIO= N WILL NOT BE AVAILABLE. All responsible sources may submit a propsal which shall be considered. The price range for this project is between $250,000 and= $500,000. NAICS233320 SIC:1541, P&S Y152.
- Web Link
-
Please click here to view more details.
(http://www2.eps.gov/spg/DOI/NPS/APC-IS/I1505020120/NA http://ideasec.nbc.gov/ecprod/owa/ec$cbd.sypfirstcount?P_SERVER_ID3=3DN= P144302&P_OBJ_ID1=3D838147)
- Place of Performance
- Address: Badlands National Park Box 6 Interior, SD 57750
- Zip Code: 57751
- Country: USA
- Zip Code: 57751
- Record
- SN00171379-W 20020921/020919213735 (fbodaily.com)
- Source
-
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)