MODIFICATION
41 -- PMC Walk-in Cooler
- Notice Date
- 6/26/2002
- Notice Type
- Modification
- Contracting Office
- Department of Agriculture, Natural Resources Conservation Service, Louisiana State Office, 3737 Government Street, Alexandria, LA, 71302
- ZIP Code
- 71302
- Solicitation Number
- NRCS-20-LA-02
- Response Due
- 7/10/2002
- Point of Contact
- Ralph Broome, Contracting Officer, Phone 318-473-7781, Fax 318-473-7831,
- E-Mail Address
-
ralph.broome@la.usda.gov
- Small Business Set-Aside
- Total Small Business
- Description
- The requirements and conditions of the combined synopsis/solicitation are hereby changed and/or clarified, as follows: (1) The 8 in. x 6 in. concrete support wall and all associated connections to the support wall are eliminated in their entirety. The cooler connection shall be directly to existing insulated concrete slab floor. Design loads and detail requirements remain the same. (2) The initial temperature of the stored product will be 70 degrees F; the loading rate of the product will be 15,600 pounds of water per day for ten days; and the time required for achieving the required operating temperature on a per day loading basis is twenty-four hours. (3) The interior connection of the chamber to concrete slab floor shall be sealed in a manner to allow hose washing of the interior concrete floor without creating damage to interior chamber wall. (4) The requirement for the door length equal to the chamber height plus eight inches is eliminated. The door length shall be the height from the chamber roof to the existing concrete floor. (5) The cooler shall not have its own floor system. The existing insulated concrete slab shall serve as the floor for the cooler chamber. (6) Support/reinforcement shall not be externally attached to the existing building structure. Support/reinforcement may be provided internal or external to the chamber. External support height shall not exceed 10 feet above the existing concrete floor grade. Internal support shall not obstruct the chamber interior and the minimum clear distance from the concrete floor to the bottom of internal support shall be eight feet. (7) External chamber height shall be no greater than ten feet measured from the existing concrete floor. (8) The requirement for roof mounting the condensing unit is eliminated. The condensing unit may be installed at ground level at a location concurred in by the Government. The condensing unit shall have an all weather cover. The date and time set for receipt of quotes is hereby changed to 4:30 P.M. (local time), July 10, 2002. No other changes necessary, all other terms and conditions remain unchanged and in full effect.
- Place of Performance
- Address: USDA-NRCS Plant Materials Center, 438 Airport Rd., Galliano, Louisiana
- Zip Code: 70354
- Country: USA
- Zip Code: 70354
- Record
- SN00099844-W 20020628/020626213140 (fbodaily.com)
- Source
-
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |