J -- DIESEL GENERATOR RENTAL FOR USNS ZEUS

Notice Date
1/22/2002
 
Notice Type
Solicitation Notice
 
Contracting Office
Department of the Navy, Military Sealift Command, MSC East - Norfork, Virginia, Bldg 238/2 B Street Camp Pendleton, Virginia Beach, VA, 23451
 
ZIP Code
23451
 
Solicitation Number
N62381-02-R-1012
 
Response Due
1/28/2002
 
Archive Date
1/28/2002
 
Point of Contact
Lawrence Iwuamadi, Contract Specialist, Phone 757-417-4593, Fax 757-417-4606, - Sandra Tyree, Supervisory Contract Specialist, Phone 757-417-4591, Fax 757-417-4606,
 
E-Mail Address
lawrence.iwuamadi@msc.navy.mil, sandra.tyree@msc.navy.mil
 
Description
Two 600 kW (continuous) package unit diesel generators, 480 volt, three phase (floating neutral), 60 Hz generators in a 20 foot ISO sound attenuated container with fuel capacity sufficient for 15 hours (minimum) operation at full load. Power Quality shall comply with MIL STD 1399, Type I. Upon a sudden load or spike demand the generator set must be capable of supplying an output of 160% of rated output for a duration of three seconds and return to a steady state condition as operating at or below rated output within ten seconds. Provide three 20 foot LSTSGU/A-400 installed (to the supply bus) cables. Plugs shall be provided and installed on the load side of the cables by others. The package unit shall include a fire suppression system that can be actuated from outside of the container, alarm system including diagnostics and audible alarm, fuel tank, and generator controls. Quotes shall identify a firm fixed price of for 8000 hours of use of either generator for the full performance period. Period of Performance will be between 15FEB02 and 01NOV02. Diesel Generator Package units are to arrive at CHEATEM ANNEX (CAX), Williamsburg VA on 15FEB02 and will be removed from the same location on 01NOV02. Proposals shall include 3 days of technical support for training and overseeing hook-ups. Hook-up work will be done by others. Proposal shall include 2 travel days to support this effort. QUESTIONS ON THIS PACKAGE SHALL BE DIRECTED TO MR. LOUIS MYERS AT (757) 417-4595/louis.myers@msc.navy .mil
 
Place of Performance
Address: Cheatham Annex (CAX), Williamsburg, VA
 
Record
SN20020123/00016308-020122123017 (fbodaily.com)
 
Source
FedBizOpps.gov Link to This Notice
(will not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.